Graco GM 1030 Instructions Manual
Graco GM 1030 Instructions Manual

Graco GM 1030 Instructions Manual

Texspray gun
Hide thumbs Also See for GM 1030:

Advertisement

Quick Links

Instructions - Parts Lists
t
GM 1030
- For portable spray application of architectural paints and coatings -
1000 psi (7.0 MPa, 70 bar) Maximum Working Pressure (Absolute)
150 psi (1.0 MPa, 10 bar) Maximum Fluid Working Pressure (Recommended)
125 psi (0.9 MPa, 9 bar) Maximum Air Working Pressure
Model 235490, Series A
Requires up to 30 SCFM (0.83 m#/min) air
CONTENTS
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grounding and Electric Requirements
Thermal Overload
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Nozzle & Disc Selection
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Flushing Guidelines
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Warranty
. . . . . . . . . . . . . . . . . . . . . . .
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 1993, Graco Inc. is registered to I.S. EN ISO 9001
Parts
TexSpray Gun
2
2
. . . . . .
5
6
7
8
9
9
10
10
11
12
13
13
14
308274M
Read warnings and instructions.
. . . . . . .
309663
. . . . . . .
309662
01808

Advertisement

Table of Contents
loading

Summary of Contents for Graco GM 1030

  • Page 1: Table Of Contents

    ..... . . GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1993, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2: Specifications

    Specifications This equipment is not intended for use with flammable or combustible materials used in places such as cabinet shops or other “factory” or fixed locations. If you intend to use this equipment in this type of application, you must comply with NFPA 33 and OSHA requirements for the use of flammable and combustible materials.
  • Page 3 The following are general Warnings related to the safe setup, use, maintenance and repair of this equipment. Additional, more specific warnings may be found throughout the text of this manual where applicable. WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: D Use equipment only in well ventilated area.
  • Page 4 D Read all instruction manuals, tags, and labels before operating the equipment. INSTRUCTIONS D Use equipment only for its intended purpose. Call your Graco distributor for information. D Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
  • Page 5: Pressure Relief Procedure

    Grounding Requirements WARNING Your system must be grounded. Read Fire and Explosion Hazard warnings, page 3. Ground sprayer with grounding clamp to earth ground when flushing sprayer. Pressure Relief Procedure WARNING Refer to you sprayer manual for Pressure Relief Procedure. Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, servicing or transporting equipment.
  • Page 6: Installation

    Installation WARNING WARNING RECOIL HAZARD Due to the high pressure fluid emitted, a strong recoil action may occur when you trigger this gun. If you are unprepared, your hand could be forced back toward your body or you could lose your bal- ance and fall, resulting in serious injury.
  • Page 7: Operation

    WARNING and less fluid = less air. EQUIPMENT MISUSE HAZARD In the GM 1030 TexSpray, the fluid pres- 4. If you cannot get a good spray pattern, try sure is relieved automatically when the adjusting the air regulator pressure or try another INSTRUCTIONS gun trigger is released.
  • Page 8: Helpful Hints

    Helpful Hints D A spraying distance of 18 to 30 in (0.5 to 1.0 m) D To spray a small, confined area, you may be able is recommended for most applications. to restrict the spray pattern sufficiently by restricting the gun’s air. For further adjustment, reduce the D Keep the gun triggered and moving as much as engine RPM.
  • Page 9: Service

    Service If air is leaking around the air valve WARNING 1. Follow the Pressure Relief Procedure. To reduce the risk of a serious injury due to the sprayer starting unexpectedly, always shut off the 2. Remove the trigger (24). engine and disconnect the spark plug before 3.
  • Page 10: Parts

    Parts 01829 Model 235490, Series A Includes items 1 to 31 Part No. Description Part No. Description 188354 RETAINING NUT 156082 O-RING SPRAY TIP DISKS 150925 GASKET, copper 235579 1/8 in. orifice 203953 LOCKSCREW, trigger 235580 1/4 in. orifice 188446 GUN BODY 235581 3/8 in.
  • Page 11: Technical Data

    Technical Data Dimensions Maximum Air Working Pressure ..125 psi (9 bar) Weight (dry, without packaging) ..34 oz (980 g) Air Requirements ... . 30 scfm (0.84 m /min) Height...
  • Page 12 Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

This manual is also suitable for:

235490