Measuring Clutch Current Draw; Solenoid - Toro Z Master Z400 Series Service Manual

Hide thumbs Also See for Z Master Z400 Series:
Table of Contents

Advertisement

Measuring Clutch Current Draw

1. Disengage the PTO, set the parking brake, turn the
ignition key to OFF, and remove the key.
2. Disconnect the PTO clutch harness from the main
harness.
3. Set the multimeter to check amps (10 amp scale).
4. Connect the positive meter lead to terminal (1) of the
main harness (Fig. 403).
Fig 403
5. Connect the negative meter lead to the clutch
harness terminal (3), Fig. 403.
6. Connect a short jumper lead from terminal (2) to
terminal (4) Fig. 403.
Z Master Z400 Service Manual
7. Turn the ignition switch to the "RUN" position. Turn
the PTO switch to the "ON" position.
8. If the meter reading is 6.5 amps or above, the
system is functioning properly. If the meter reading
is below 6.5 amps, check the electrical system for
problems (i.e., the battery, ignition switch. PTO
switch, or wiring harness). Make sure the negative
side of the wiring has a good connection to chassis
ground.

Solenoid

Purpose
The solenoid's purpose is simply to connect the battery
to the starter motor when the ignition switch is turned
to "START". The solenoid is used to protect the ignition
switch from the high current drawn by the starter motor.
Location
The starter solenoid is located under the left hand fuel
tank (Fig. 404).
diag 3-7
ELECTRICAL
Fig 404
PICT-0200
6
6-13