Magnetometer
In the event of Magnetometer failure:
•
Inspect physical placement U6140 and their related components on main PCB
board.
•
Connect the board to a display and power the board/display with battery or factory
cable. Launch CQA app, test each magnetometer. Look for magnetometer on all
axis X,Y,Z. As you rotate the board orientation, magnetometer reading will register
reading accordingly.
MOTOROLA CONFIDENTIAL