To Operate From A Remote Foam Supply; Battery Charging - HALE MC50 Operation Manual

Minicafs 2.1a operating manual mc50
Table of Contents

Advertisement

TO OPERATE FROM A REMOTE FOAM SUPPLY

Foam agent can be inducted out of conventional commercial canisters. The base of the
canisters must be above the FoamLogix Pump and the MiniCAFS. A suitable dip tube should
be manufactured for the suction line. The bypass pipe should be fed back into the foam
canister.
Note The FoamLogix must be re-primed each time the foam canister is changed.
Note The system will not have the protection of a low foam level switch, and if the foam
supply is exhausted, air may be drawn into the FoamLogix Pump, and "Slugflow" may
result.

BATTERY CHARGING

A battery charging plug is included on the unit and a fuse (14, 16, page 7) rated at 10 Amps
is installed between this connector and the battery to prevent jump-starting a dead battery
through this connection.
©Hale Products Europe. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
MiniCAFS 2.1A Operating Manual
GP/211/05 Issue 2. April 2005