en Troubleshooting
Fault
Appliance door does not
open at the end of the Eco
50° programme.
Appliance door automatic-
ally opens too wide at the
end of the Eco 50° pro-
gramme.
Appliance door does not
open.
46
Cause
The safety device will switch
Eco drying off.
Door is not correctly adjus-
ted.
Wrong screws used to ad-
just the door gap.
Door is not correctly adjus-
ted.
Appliance has no power.
Appliance door and door
seal are soiled.
Automatic door opening is
not in home position.
Troubleshooting
If the screws used here are too
long, this may deactivate Eco dry-
ing.
Call "Customer Service."
→ Page 59
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
The door gap must be at least
70 mm - 100 mm.
Use size 4X30 screws to adjust the
door gap.
The screws are included in the
scope of supply.
If the screws used here are too
long, this may deactivate Eco dry-
ing.
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
Check the mains plug and fuses.
Position the emergency release
1.
supplied on the top right and left of
the cabinet panel.
Open the appliance door by pulling
2.
lightly.
Clean the appliance door and door
seal with a damp cloth and a little
washing-up liquid.
Wait one second after closing the
appliance door.