Summary of Contents for American Dynamics AD1200EXP MCS
Page 1
Hard-wire Controller Expander Installation Instructions The manual describes the installation procedures for the American Dynamics AD1200EXP MCS Hard-wire Controller Expander. Before installation, become familiar with all of the special features and warnings associated with this equipment. Store this manual in a safe, convenient location for future reference.
Page 2
This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system. NOTE: Information furnished by SENSORMATIC is believed to be accurate and reliable.
Page 3
The installation of this product should be made by qualified service personnel and should conform to all local codes. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVERS (OR BACK) . NO USER-SERVICEABLE PARTS INSIDE.
Snap-on connectors enable simple interconnections between multiple AD1200EXP units, between pan/tilt sites, and between CCTV switching systems. A 30-inch wire harness is provided with the AD1200EXP for direct connection to the AD1200A Controller. FEATURES • Operate four Pan/Tilts from One Control Site (Expandable to 16 Pan/Tilts) •...
AD1200EXP units when cascading multiple EXP units together (see Figure 3). A ground bolt provides a common ground connection between the AD1200EXP and the individual pan/tilt sites and related equipment. Four 14-pin connectors provide control outputs for pan/tilt and automatic lens functions.
AD1200EXPs in a standard EIA rack. Power The AD1200EXP is configured for use with 24VAC power. A single AD1200EXP unit receives its power directly from the AD1200A Hard-wired Controller. In cases of multiple AD1200EXP units, power is derived in two ways.
Page 9
AD1200EXP Figure 4 - Single AD1200EXP Expander -to- AD1200A Hard-wired Controller Connection AD1200EXP DOWN RIGHT LEFT AUX 1 COMMON IRIS FOCUS LENS 14-Pin Connector 14-Pin Mating Connector AUTO LENS SCAN AUX 2 P/T & AUX RETURN ZOOM 24VAC 24VAC AD1200A Controller...
Beginning with the suitable ground lead between the ground terminals located on the rear panel of each AD1200EXP unit (see Figure 5). NOTE: Proper grounding requires a minimum 18AWG solid Connect the ground lead between the FIRST AD1200EXP unit and the ground terminal on the rear panel of the AD1200A Hard-wired Controller (see Figure 6).
For the FIRST AD1200EXP Unit in a Series: Connect the 14-pin connector of the FIRST (Unit #1) AD1200EXP in a series to the 14-pin mating connector on the rear panel of the AD1200A Controller (see Figure 7). NOTES: Refer to Table 1, page 4, and Figure 4, page 5, for a...
Page 13
(see Figure 8, page 11) AD1200EXP -to- AD1200A Controller Wire Harness Control Connections NOT SHOWN (see Figure 8, page 11) Figure 7 - Power Connections to Multiple AD1200EXP Units AD1200EXP Unit #1 24VAC POWER 24VAC COMMON Stepdown Transformer 120VAC-to-24VAC (North America)
Pin #1 of the AD1200 Hard-wire controller 14-pin connector is used for the Tilt UP function (see Table 3). Thus, the Tilt UP lead of ALL the AD1200EXP units connects to pin #1 of the 14-pin connector. Likewise, pin #2 of the AD1200 Hard-wire controller 14-pin connector is the Tilt DOWN function (see Table 3).
Page 15
LEFT - Pin 4 LENS COMMON - Pin 9 LENS Ground Figure 8 - Multiple AD1200EXP Unit -to- AD1200A Hard-wired Controller Connection AUX 1 - Pin 5 AUX 2 - Pin 6 P/T & AUX COMMON - Pin 8 IRIS - Pin 1 0...
After tightening the clamp-screw, gently pull on the wire to verify that it is securely held in place. Attach the 14-pin connector to the appropriate mating connector (location 1, 2, 3, or 4) on the AD1200EXP rear panel. Pin #...
Page 17
AUX 2 AUX 2 AUX 1 AUX RETURN DOWN RIGHT PAN/TILT RETURN LENS COMMON FOCUS IRIS COMMON PAN/TILT RETURN RIGHT DOWN Figure 9 - Pan/Tilt -to- AD1200EXP Connection INSTALLATION AD1240 Pan/Tilt LEFT IRIS FOCUS ZOOM AD1200EXP ZOOM AD1240 Pan/Tilt LEFT...
INSTALLATION CCTV Switcher System Connection AD1200EXP units provide a 5-pin connector for use with CCTV switcher systems. Each AD1200EXP unit is provided with one 5-pin strap harness and two 5-pin mating connectors. AD1200EXP to AD1412 Series Switcher Connection The AD1200EXP is designed for complete operating compatibility with the AD1412 and AD1412L Sequential Switchers.
SETUP SETUP 4-Position DIP Switch A 4-position DIP switch configures the AD1200EXP for the number of operational cameras and for use within a CCTV switching system. The 4-position DIP switch is mounted on the AD1200EXP rear panel (see Figure 12).
AD1200EXP OPERATION Single AD1200EXP Unit Operation A single AD1200EXP unit provides operational control to a maximum of four pan/tilt sites. 1. Press the appropriate pushbutton (1-4) to select the desired pan/tilt site (see Figure 13). 2. Select the desired pan/tilt function on the AD1200A Hard- wired Controller.