The Tracker Ball provides variable speed control of a
camera's pan and tilt. The zoom and focus buttons lets
you control a camera's zoom and focus. Figure 3-12
shows the default button setup.
The T
T
's menu mode (Error! Reference
OUCH
RACKER
source not found.) lets you perform system setup and
test procedures. To enter the menu mode, you press the
Menu button on the keypad, and the first two functions
of the vertical, scrollable menu appears on the LCD
screen.
Figure 3-13. Menu Options and Controls
Define Sequence
Setup View
Record Pattern
LCD
Auto Alarm Ack
Screen
Alarm Actions
Tog Zoom / Focus
Show Sys Info
Reset Dome
Port Settings
Tog Primary / 2nd
Ping Dome / TTR
Set Time/Date
Event Setup
Event Timers
Camera Titles
Monitor Setup
Select Language
Zoom buttons
Adjust V-phase
Adj Backlighting
select top line
Adj Keyclick Vol
Keyclick ON/OFF
You use the Tracker Ball to scroll through the menu.
When the LCD screen displays the function you want,
you press either zoom button to select the option
displayed on the top line or either focus button to select
the option displayed on the bottom line.
Switching Primary and
Secondary Functions between
Controller Units
The Tog Primary/2nd function lets you designate which
T
T
is the primary unit and which is the
OUCH
RACKER
secondary unit in a two T
OUCH
addition to its normal functions, the primary T
T
is responsible for SensorNet polling and
RACKER
alarm monitoring.
1. Press Menu.
2. Use the Tracker Ball to scroll down the menu to
Tog Primary/2nd.
3. Press the zoom (top line) or focus (bottom line)
button to select the Tog Primary/2nd menu option.
*Primary Unit
*Primary Unit
Secondary Unit
Secondary Unit
Focus buttons
select bottom line
Tracker Ball
scrolls through
menu options
T
system. In
RACKER
OUCH
AD32 SYSTEM
3-19
4. Press Next to toggle between using the primary unit
for SensorNet polling and alarm monitoring or as
the secondary unit with limited user functionality.
5. Press Menu to reset the controller as a primary or
secondary unit.
The controller will reboot and return to the Camera
Control Mode.
Performing SensorNet Ping
Test
The Ping Dome/TTR function lets you test SensorNet
devices by sending repeated echo (ping) test messages
to them and receiving responses from them. A robust
network connection should have 100% successful pings.
1. Use the number buttons to select a dome to test, then
press Camera.
2. Press Menu.
3. Use the Tracker Ball to scroll down the menu to
Ping Dome/TTR.
4. Press the zoom (top line) or focus (bottom line)
button to select the Ping Dome/TTR menu option
and to start the ping test on the selected dome. The
LCD screen displays the following message:
*
=Device being
tested
*Dome
Tx=0006
*Dome
Tx=0006
TTR
Bad=0002
TTR
Bad=0002
5. Press Next to perform the ping test on the secondary
T
T
controller unit.
OUCH
RACKER
6. Press Menu to exit.
Off-line domes or fixed cameras will generate a warning
beep and disallow use of the SensorNet network test.

Adjusting Camera V-Phase

The Adjust V-Phase function lets you adjust the vertical
synchronization of the selected camera. This lets you
switch cameras without experiencing vertical roll on the
viewing monitor. The adjustment requires the use of an
oscilloscope.
1. Press Menu.
2. Use the Tracker Ball to scroll down the menu to
Adjust V-Phase.
INSTALLATION
No. of pings
transmitted
No. of failed
responses