F100 faulty
Check resistance of F100 (0Ω)
V100 faulty
Check resistance of V100 (50KΩ in circuit)
L104 faulty Vcharge
Check resistance of L104 (0Ω)
L105 faulty Charge ground
Check resistance of L105 (0Ω)
C103 faulty short circuit on Vcharge
Check resistance of C103 (50KΩ in circuit)
N101 faulty/ poor soldering
Check PWMOUT on Pin 7 (1 Hz standard charger / 32Hz fast charger)
Check if CHARLIM on Pin 9 is 2.8V DC
N100 faulty/ poor soldering
Change if any A/D value is out of limit but the DC voltages are ok.
If DC voltages are wrong, check corresponding voltage dividers
Check PWMOUT on Pin 56 (1 Hz standard / 32 Hz fast)
X100 faulty/ poor soldering
Check connection of Vcharge; charge ground; charge control
X101 BSI; X102 BTEMP
Check connection if battery size or battery temp A/D are out
of limit
V102 faulty
Check if there is a short circuit in charge control line
Energy management Calibration
If charging stops to early
If message "not charging appears on LCD"
If any part in charging circuit has changed
If any A/D value is out of limit, check the corresponding
DC Voltages on CCONT