Viking C-3000 Product Manual

Viking C-3000 Product Manual

Apartment entry system
Hide thumbs Also See for C-3000:

Advertisement

Quick Links

DESIGNED, MANUFACTURED AND SUPPORTED IN THE USA
VIKING
SECURITY & COMMUNICATION
Add Apartment Entry Without Rewiring
This entry system is designed to utilize a building's
existing telephone wiring and to address a variety
of apartment entry applications. Viking's C-3000
Entry System provides secure multi-tenant building
access, without the need for any C.O. lines; the
only requirement is that each tenant have a touch-
tone telephone set wired to their apartment. The
C-3000 performs equally as well in installations
where C.O. lines are present. An individual C-3000
module has a 12-tenant capacity; for larger appli-
cations, a maximum of eight (8) C-3000 modules
can be interconnected, allowing a total system ca-
pacity of up to 96 tenants. A C-3000 system con-
sists of at least one Primary C-3000 module, and
as many as seven Secondary modules.
From either of two entry doors, visitors may ring a
tenant's telephone with a distinctive cadence, alert-
ing the tenant of their arrival. The C-3000 provides
call waiting tones if the tenant's line is in use. The
tenant may then converse freely with the visitor via
their existing telephones. Once identified, the ten-
Features
• Utilizes building's existing telephone wiring, yet
functions with or without tenant CO lines
• No monthly charges for a dedicated line
• Tenants do not require phone service
• Programmable keyless entry code for each
tenant
• Distinctive ring cadence and call waiting
• Programmable from dedicated programming
phone
• Supports (2) entry doors and (2) door strikes
• 12-tenant capacity may be expanded to 96
tenants at any time
• Compatible with Viking's vandal resistant
K-1700-3, K-1900-8 or any Touch Tone phone
• May be wired so that tenants may talk to
visitors without disrupting C.O. modem
transmissions
• Allows visitors to leave voice messages on
tenants personal answering machines
www.VikingElectronics.com
Information: (715) 386-8861
PRODUCT
MANUAL
ant can let the visitor in by entering a single touch-
tone on the keypad of the tenant's telephone set.
The C-3000 keyless entry feature supports unique
entry codes for each tenant. As a measure of se-
curity, the codes can be easily changed as tenants
move in and out of the building. A postal lock fea-
ture is also supplied as an added convenience.
• Apartments and condominiums
• Buildings where some or all tenants lack phone
service
• Supervised living
• Student housing
• Retrofit older construction
Power: 120VAC / 13.8VAC 1.25A, UL listed
adapter provided
Dimensions: 211mm x 160mm x 46mm (8.30" x
6.30" x 1.80")
Shipping weight: 1.0kg (2.2 lbs.)
Environmental: 0° C to 32° C (32° F to 90° F) with
5% to 95% non-condensing humidity
Talk battery: 40VDC
Relay contact ratings: 5A @ 30VDC / 250VAC
Maximum System Door Phones/Door Strikes:
(2) each
Maximum System Tenant Capacity: 96 - using
(8) C-3000 modules
Ring Generator:
maximum
Connections: (1) RJ-21X female 25-pair, (3) RJ-
11 female, (13) terminal block positions
C-3000
Apartment
Entry System
July 8, 2020
Applications
Specifications
90V AC nominal, 7 REN

Advertisement

Table of Contents
loading

Summary of Contents for Viking C-3000

  • Page 1 (8) C-3000 modules can be interconnected, allowing a total system ca- pacity of up to 96 tenants. A C-3000 system con- sists of at least one Primary C-3000 module, and as many as seven Secondary modules.
  • Page 2: Preparing The Installation

    (if applicable). If the tenant phone wiring is not currently cabled though a "66" block or blocks, it will be necessary to install "66" block(s) at this time to facilitate the installation of the C-3000 system.
  • Page 3: Standard Wiring

    Note: If the Primary C-3000 is powered up first, it is normal for the E. Standard Wiring power LED’s of all C-3000’s to light. Bridged Bridged Module ID #1 “Primary” for Apts 1-12 Row 1 Row 2 Row 3 Row 4 VIKING C.O.
  • Page 4: Detailed Example

    In this scheme, the modem will be connected to the Y/BK pair of the RJ-14 which is wired ahead of the C-3000, directly to the C.O. line. Use a 2 line splitter to connect the modem to the Y/BK pair.
  • Page 5 #00. There is no factory default setting for this value, nor is there a requirement that it be set. Relay Activation Time: The period of time (in seconds) for which a C-3000 door strike relay will remain activated, after having been given an activation code.
  • Page 6: Operation

    D. General C-3000 System Setup The following procedures are to be performed on each module in the C-3000 system, one module at a time. Note that while each module needs to be programmed separately, it is standard practice to make all of the following settings identical, for all modules.
  • Page 7: Keyless Entry

    The primary C-3000 has not been properly programmed with the "number of modules" in the stack (##8 memory lo- cation). The primary C-3000 must be told how many C-3000's are in the stack and this is set to one by default. Pro- gram the primary with the correct number of units in the stack.
  • Page 8: Warranty

    Product Support: (715) 386-8666 Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.