Wiring The Power Input Connector; Wiring The Power Output Connectors - Graco G-Barrier Instructions Manual

Power barrier for hazardous locations
Table of Contents

Advertisement

Installation
Wiring the Power Input
Connector
Use a Class 2 Power Supply only.
The input power connector, provided with the barrier, is
field-wireable with screw terminals.
Black wire
Red wire
F
. 6: Wiring Power Input Connector
IG
12
Wiring the Power Output
Connectors
The output connectors all have power on pin 2. Pins 1,
3, and 5 are all connected to ground. Pins 4 and 6 are
not connected. NOTE: If you are making your own cable
connections, the wire colors may differ.
Blue
Brown
Black
Black
F
. 7: Wiring When Using 16K509 or 16K615 Cables
IG
ca
PART NO.
MODEL
SERIES
SERIAL NO.
F
. 8: Wiring Power Output Connectors, Front View
IG
Input
8
7
12 - 24 V
DC
24 W
HAZARDOUS
Status
Ground
1A
Output
2A
Ground
3A
NC
4A
Ground
5A
NC
6A
Green
Status
light
Ground
1B
Output
2B
Ground
3B
NC
4B
Ground
5B
NC
6B
Status
Ground
1C
Output
2C
Ground
3C
NC
4C
Ground
5C
NC
6C
3A5056B

Advertisement

Table of Contents
loading

Table of Contents