Toshiba FT-3809 BK Service Manual page 57

Table of Contents

Advertisement

Base Unit
Receiver
Sensitivity (-106 dBm,
800 Hz, CCITT)
Channel Bandwidth
Receiver Noise Figure
Sensitivity (25 dB Sinad)
Image Rejection (RF)
Adjacent Channel Rejection
Receiver Muting Level
Transmitter
Transmit Power
Output Frequency Range
Channel Spacing
Radiated Field Strength
Antenna Polarization
Transmitter Frequency
Stability, 0 ° C to 50 ° C
Modulation Method
Frequency Deviation
Modulation Data Rate
Telephone Dial Unit
Pulse Dialing
a. Dialing Rate
b. Break Ratio
Tone Dialing
a. Frequency
Row1
Row2
Row3
Row4
Column1
Column2
Column3
b. Minimum Level on Single Tone
Low Group
High Group
c. Maximum Level
on Freq. pair
d. High Group to
Low Group
Unit
Nominal
dB
25
KHz
150
dB
-
dBm
-
dB
-
dB
-
dBm
Unit
Nominal
dB µ V/m
92
MHz
-
KHz
300
mV/m, @ 3 m
-
-
Vertical
KHz
-
-
FSK
KHz p-p
50
kbps
50
Unit
pps
%
Hz
Hz
Hz
Hz
Hz
Hz
Hz
dBm
dBm
dBm
dBm
56
Limit
>30
<5.5
<-106
at duplexer
>60
>60
-108
-107 to -109
Limit
90-94
902.3-905.0
-
<50
-
+ 5
-
+ 5
-
Nominal
Limit
10
8-11
60
54-68
697
+1.5%
770
+1.5%
852
+1.5%
941
+1.5%
1209
+1.5%
1336
+1.5%
1477
+1.5%
-5.5
-4 ~ -7.5
-3.5
-2 ~ -5.5
-5
0
2
0-4

Advertisement

Table of Contents
loading

Table of Contents