Appliance Break-In; Heat Management - Heatilator NNXT33-IFT Owner's Manual

Direct vent heater
Hide thumbs Also See for NNXT33-IFT:
Table of Contents

Advertisement

H. Appliance Break-In
Follow the initial break-in procedure below to cure the
materials used to manufacture the fireplace and the
finishing materials around it.
• The fireplace should be run three to four hours
continuously on high.
• Turn the fireplace off and allow it to cool completely.
• Remove fixed glass assembly. See Section 4.B.
• Clean fixed glass assembly. See Section 4.B.
• Replace the fixed glass assembly and run continuously
on high an additional 6-12 hours.
Note: Some IPI systems have a safety feature that
automatically shuts down the fireplace after 9 hours of
continuous operation without receiving a command from
the remote control. If this occurs, restart the appliance.
NOTICE! Open windows for air circulation during fire-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
I. Heat Management
The NNXT models have a variable burn rate which is
controlled by the remote control. Therefore the flame
height is adjustable.
The flame height may be adjusted as desired by locating
the flame option on the remote control and adjusting up
or down to desired flame height.
12
Heatilator • NNXT33-IFT, NNXT33L-IFT, NNXT36-IFT, NNXT36L-IFT Owner's Manual • 2628-981 Rev. D • 1/21
Optional Heat Management Systems
An optional heat management system, which allows the
heat from the appliance to be redirected as desired, may
be installed with this appliance. It may be either a Heat-
Zone
-Gas, which diverts heat into an adjacent room,
®
and/or a HEAT-OUT-GAS which will divert heat outside
the home/building.
Refer to Section 6 of the appliance installation manual to
confirm which of the heat management systems may be
installed together. All heat management systems must be
installed by a qualified service technician at the time of
appliance installation.
Optional Heat-Zone
-Gas Kit
®
The Heat-Zone
-Gas heat management option is avail-
®
able for use with the NNXT-IFT appliances and must be
used in conjunction with the IFT-RC400 remote control.
The Heat-Zone Kit draws heat from your fireplace to an
adjacent room in your home, up to 20 feet away.
Optional Heat-Out-Gas Kit
The Heat-Out-Gas heat management option is available
for use with the NNXT-IFT appliances and must be used
in conjunction with the IFT-RC400 control. The Heat-
Out-Gas kit draws heat from your fireplace and directs it
outside, up to 25 feet away.
Optional Heat-Duct Kit
The Heat-Duct heat management option is available
for use with the NNXT-IFT appliances. The Heat-Duct
redistributes heat from the fireplace via the furnace
ductwork.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nnxt33l-iftNnxt36-iftNnxt36l-ift

Table of Contents