Applicable Standard - Panasonic LH2H Series Manual

Din half size hour meter
Table of Contents

Advertisement

LH2H
2. PC board mounting type
Item
Input method
No. digits
Rated operation voltage
Allowable operation voltage range
Current consumption
Measurement time range
Min. input signal width
Input method
Start
input
Input impedance
Residual voltage
Min. input signal width
Input method
Reset
input
Input impedance
Residual power
Break down voltage (initial)
Insulation resistance (initial)
3. Common
Item
Time accuracy
Functional
Vibration resistance
Destructive
Functional
Shock resistance
Destructive
Operation temperature
Storage temperature
Ambient humidity

Applicable standard

Safety standard
(EMI)EN61000-6-4
Radiation interference electric field strength
Noise terminal voltage
(EMS)EN61000-6-2
Static discharge immunity
EMC
RF electromagnetic field immunity
EFT/B immunity
Conductivity noise immunity
Power frequency magnetic field immunity
Type
0 to 999999.9h
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Min. 100 MΩ (measured at 500 V DC) Measurement location same as for break down voltage.
Type
10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm (10 min. on 3 axes)
10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm (1 hr. on 3 axes)
EN61010-1
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
PC board mounting type
Non DC voltage input
7 digits
3 V DC
2.7 to 3.3 V DC
Max. 20 µA (max. 200 µA during reset input)
200 ms
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
10 ms
Non-voltage input using contacts or open collector connection
When shorted: Max. 10 kΩ
When open: Max. 750 kΩ
Max. 0.5 V
Panel mounting/PC board mounting types
±100 ppm (25°C 77°F)
Min. 98 m/s
(4 times on 3 axes)
2
Min. 294 m/s
2
(5 times on 3 axes)
–10 to +55°C
+14 to +131°F
–25 to +65°C
–13 to +149°F
35 to 85% RH (non-condensing)
EN55011 Group1 ClassA
EN55011 Group1 ClassA
EN61000-4-2
4 kV contact
8 kV air
EN61000-4-3
10 V/m AM modulation (80 MHz to 1 GHz)
10 V/m pulse modulation (90 MHz)
EN61000-4-4
2 kV (power supply line)
EN61000-4-6
10 V/m AM modulation (0.15 MHz to 80 MHz)
EN61000-4-8
30 A/m (50 Hz)
0 to 9999h59.9m
(without frost or dew)
(without frost or dew)
Pollution Degree 2/Overvoltage Category III