Fujitsu AIRSTAGE AUXS018GLEH Operating Manual

Indoor unit (3d flow cassette type)
Hide thumbs Also See for AIRSTAGE AUXS018GLEH:

Advertisement

Quick Links

AUXS018GLEH
AUXS024GLEH
OPERATING MANUAL
INDOOR UNIT (3D flow cassette type)
Keep this manual for future reference.
BEDIENUNGSANLEITUNG
INNENGERÄT (3D Fluss-Kassettentyp)
Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf.
MODE D'EMPLOI
UNITÉ INTÉRIEURE (Type cassette à flux 3D)
Conservez ce manuel pour pour toute référence ultérieure.
MANUAL DE FUNCIONAMIENTO
UNIDAD INTERIOR (Tipo casete de flujo 3D)
Conserve este manual para posibles consultas futuras.
MANUALE DI ISTRUZIONI
UNITÀ INTERNA (Tipo a cassetta con flusso 3D)
Conservare questo manuale per consultazione futura.
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ (τύπος κασέτας με ροή 3D)
Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά.
MANUAL DE FUNCIONAMENTO
UNIDADE INTERIOR (tipo de cassete de fluxo 3D)
Guarde este manual para consulta futura.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ВНУТРЕННИЙ МОДУЛЬ (кассетный тип с 3D потоком)
Сохраните данное руководство для последующего использования.
KULLANIM KILAVUZU
İÇ ÜNİTE (3D akış kaset tipi)
Bu kılavuzu ileride başvurmak üzere saklayın.
Refer to the rating label with the serial number.
MADE IN P.R.C.
[Original instructions]
PART No. 9383490019

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AIRSTAGE AUXS018GLEH

  • Page 1 OPERATING MANUAL INDOOR UNIT (3D flow cassette type) Keep this manual for future reference. BEDIENUNGSANLEITUNG INNENGERÄT (3D Fluss-Kassettentyp) Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf. MODE D’EMPLOI AUXS018GLEH AUXS024GLEH UNITÉ INTÉRIEURE (Type cassette à flux 3D) Conservez ce manuel pour pour toute référence ultérieure. MANUAL DE FUNCIONAMIENTO UNIDAD INTERIOR (Tipo casete de flujo 3D) Conserve este manual para posibles consultas futuras.
  • Page 2: Table Of Contents

    OPERATING MANUAL ● Do not apply any heavy pressure to radiator fins. ● Do not use inflammable gases near the air conditioner. PART No. 9383490019 ● Do not touch the piping during operation. VRF system indoor unit (3D flow cassette type) ●...
  • Page 3: Manual Auto Operation

    AIRFLOW DIRECTION Control unit (optional) Types of remote controllers: ● Wireless remote controller The vertical and horizontal airflow direction can be controlled with the ● Wired remote controller remote controller. ● Simple remote controller For operation method, please refer to the operating manual of each Horizontal airflow direction device.
  • Page 4: Operating Tips

    Low ambient cooling Vertical airflow direction ● When the outdoor temperature drops, the outdoor unit’s fans may The vertical airflow direction can be controlled with the remote controller. switch to Low Speed, or one of the fans may stop intermittently. Heating performance ●...
  • Page 5: Cleaning And Care

    CLEANING AND CARE 2. Hold the handle to lift the air filter. * The diagram shows the removed intake grille for explanatory purpose. Handles CAUTION ● Before cleaning the unit, be sure to stop the unit and disconnect the Air Filter power supply.
  • Page 6: Troubleshooting

    TROUBLESHOOTING 7. Insert three hooks. The following conditions are not breakdowns or op- eration failures. Does not operate immediately: ● If the unit is stopped and then immediately started again, the com- Hooks pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
  • Page 7: Specifications

    SPECIFICATIONS The following conditions may not be breakdowns so check again. Does not operate at all: MODEL AUXS018GLEH AUXS024GLEH ● Has there been a power failure? POWER SOURCE 220-240V ~ 50Hz, 230V ~ 60Hz ● Has a fuse blown out, or a circuit breaker been tripped? AVAILABLE VOLTAGE RANGE 198 to 264 V (50Hz) , 198 to 253 V (60Hz) ●...