Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges, within which the
air conditioner can be used.
If the air conditioner is used at...
High temperature
Low temperature
High humidity levels
12
E-
Then...
The automatic protection feature may be triggered and
the air conditioner stopped.
A water leakage or some other
malfunction may happen if the heat exchanger freezes.
Water may condense on and drip from the surface of the indoor unit
if it is used for a long periods.
Mode
Outdoor Temperature
Heating
-5°C to 24°C approx.
Cooling
-5°C to 43°C approx.
Drying
-5°C to 43°C approx.
The standardized temperature for heating is 7°C.
If the outdoor temperature drops to 0°C or below, the heating capacity
can be reduced depending on the temperature condition.
If the cooling operation is used at over 32°C(indoor temperature), it does
not cool at its full capacity.
Indoor Temperature
Indoor Humidity
15°C to 27°C approx.
21°C to 32°C approx.
80% or less