Field Calibration Check

CHECKING ACCURACY – HORIZONTAL BEAM, SCAN DIRECTION (FIG. 5)
Checking the horizontal scan calibration of the laser requires two walls
9 m (30') apart. It is important to conduct a calibration check using a
distance no shorter than the distance of the applications for which the
tool will be used.
TABLE 1
1. Attach the laser to a wall using its pivot bracket, with the laser
2. Turn on the laser's horizontal beam and mark the beam position on
3. Pivot the laser to the extreme left (–90 degree position) and mark
4. Pivot the laser to the extreme right (+90 degree position) and mark
DW089K-XJ_DW89CG-XJ User Manual - EU - FEB 2019 - Part A.indd 63
should be dried first with a soft dry cloth.
Distance
Between Walls
9.0 m (30')
12.0 m (40')
15.0 m (50')
facing straight ahead toward the opposing wall (0 degree position).
the opposing wall directly across from the laser. Always mark the
centre of the beam's thickness.
the beam position on the opposing wall.
the beam position on the opposing wall.
Allowable Distance
Between Marks
3.0 mm (1/8")
4.0 mm (5/32")
5.0 mm (7/32")