Ventilation
C
Min. 35mm
A
B
The following instructions are critical if the vent kit, as supplied, is not fitted:
If the kick board vent kit cannot be used then it is important to fit a standard HydroTap vent kit, which ensures
heat dissipation through natural convection via installed vents. For high use applications, where the cupboard
space temperature is near 35°C, or higher, an auxillary ventilation kit must be fitted. (contact your local
service centre for availability).
Note: The vent kit has to be installed in a way that allows air to be drawn in from the bottom of the cupboard
and expelled through the top of the cupboard. Therefore placement of the outlet vent should be towards the
top of the door (Option 1) or on the side of the cupboard (Option 2).
Side outlet vent
(Option 2)
Front inlet vent
Door outlet
louvre
Warm Air OUT
(Option 1)
Cool Air IN
801525NZ - Chilled HydroTap Installation Instructions - Aug 2015 - v2.00
Page 15 of 20