Technical Specifications - STEINEL IR180UP Information

Hide thumbs Also See for IR180UP:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8

Technical specifications

IR 180 UP
Dimensions:
(H x W x D) 80 x 80 x 55 mm
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos
inductive load at 230 V AC
4 x 58 W each max., C ≤ 88 µF
operating on 230 V AC
Connection:
230 V, 50 Hz
3-lead connection (L, L', N)
Contact gap:
between the contacts when unit is switched OFF
Installation height:
approx. 1.1 + 2.2 m
Sensor technology:
Infrared sensor
Transmission output:
Angle of coverage:
180° with 90° angle
of aperture
Reach:
8 m max.
Twilight setting:
2 - 2000 lux
Time setting:
5 sec. - 30 min.
Permanent light:
switchable (4 h)
Permanent light OFF: switchable
*
1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast
(total capacity of all connected ballasts below the value specified).
*
2)
Installation above a door.
Disposal
Electrical and electronic equipment,
accessories and packaging must be
recycled in an environmentally com-
patible manner.
Do not dispose of electrical
and electronic equipment as
domestic waste.
HF 360 UP
= 0.5,
j
*1)
*2)
5.8 Ghz high frequency
approx. 1 mW
360° with 140° angle
of aperture
1 - 8 m
continuously adjustable
2 - 2000 lux
5 sec. - 30 min.
switchable (4 h)
switchable
EU countries only: Under the current
European Directive on Waste Electri-
cal and Electronic Equipment and its
implementation in national law, electri-
cal and electronic equipment no long-
er suitable for use must be collected
separately and recycled in an environ-
mentally compatible manner.
- 16 -
Installation
Note for IR 180 UP:
The installation position should be at
least 1 m from a light, since heat radi-
ation may trigger the system.
Installation procedure:
1. Pull the mains lead out of the flush
box and strip the insulation from
the individual leads.
Connecting the supply lead
(refer to Ill. on page 4)
The mains lead consists of a 3-phase
cable.
L = phase conductor
(usually black or brown)
N = neutral conductor
(usually blue)
L' = phase conductor
(usually black or brown)
If in doubt, the cable must be identi-
fied with a voltage tester. Switch OFF
the current again. Phases (L) and (L')
in addition to the neutral conductor
(N) are connected to the terminal
block. A protective-earth conductor is
not required.
Important:
Reversing the connections may result
in damage to the unit.
(IR 180 UP / HF 360 UP)
2. Push the basic element b into the
flush box a and arrange horizontal-
ly. Take care that the cables are not
pinched. Tighten both screws on
the expansion claw until the basic
element is firmly seated or screw
with socket fixing screws on the
support ring.
3. Apply the cover frame c and sur-
round d and carefully mount the
sensor unit e without tilting.
4. Once the mains connection has
been made, the sensor switch can
be operated (refer to Functions
section).
The adjustment controls for the func-
tions are concealed behind the folding
design shade. Push in the catch on
the sensor unit with a screwdriver and
fold the design shade forwards.
Note:
Parallel switching of IR 180 UP and
HF 360 UP is possible. Nevertheless,
a neutral lead must be present on
each concealed box. The max. output
to be switched does not increase as a
result.
- 17 -