13. PREVENT TO RESTART FOR 3 MINUTES ( 3 MINUTES ST )
The compressor won't enter operation status for 3 minutes
after a compressor is stopped, even if any operation is given.
14. 4-WAY VALVE EXTENSION SELECT
At the time when air conditioner is switched from Cooling mode
to Heating mode, a compressor is stopped, and a 4-way valve is
switched in 3 minutes later after a compressor stopped.
15. AUTO RESTART
If power is interrupted by blackout, etc. in operation,
the operation contents at that time are memorized.
And when power is recovered, operation is automatically
resumed with the memorized operation contents.
When power is interrupted and recovered during timer operation,
timer operation is canceled, but only setting time is memorized.
Operation contents memorized
Operation mode
Set temperature
Set airflow
Timer mode and timer time (Set by wireless remote control)
MIN. HEAT (Wireless remote control is in use)
ECONOMY
Air flow direction (Swing setting)
Individual air flow direction (Swing setting)
Human sensor auto saving (setting/timer)
Human sensor auto off (setting/timer)
Energy saving setting
Each central setting