Bosch Greenstar Series Installation And Service Instructions For Contractors page 37

Residential gas condensing boiler
Table of Contents

Advertisement

If multiple boilers are installed in a row, allow at least 1 foot (305 mm)
clearance between the vent termination of one and the combustion air
intake of the other.
The combustion air inlet is located at least 1 ft (305 mm) above the
upper edge, the expected snow line or roof surface (in Canada, at least 1
1/2 ft (457 mm) ( Fig. 31 [Y
], page 31).
A
Vent termination must be located at least 7 ft (2135 mm) above public
traffic routes ( fig. 31 [X
], page 31). Condensate can exit at the
5
terminal end. Ensure that condensate spilling from the termination does
not create a hazard or a nuisance.
Do not allow expose vent pipes outside the building to extend past the
recommended distance. Condensate can freeze and block the flue
outlet.
Vent termination must be at least 3 ft (915 mm) away from adjoining
walls, inside corners and 5 ft (525 mm) below the roof overhang
( Fig. 31 [X
], [X
], page 31).
2
4
Do not extend exposed vent pipe outside the building beyond
recommended distance. Condensate could freeze and block vent pipe.
Material
Item
PVC schedule 40, 80
2" (50 mm) Vent or air
pipe and fitting
PVC-DWV
CPVC schedule 40, 80
PVC schedule 40, 80
3" (76 mm) Vent or air
pipe and fitting
PVC-DWV
CPVC schedule 40, 80
PP rigid venting
3" (80 mm) vent or air
pipe M&G Duravent
PolyPro and
Centrotherm InnoFlue
PP rigid venting
2" (50 mm) vent or air
pipe M&G Duravent
PolyPro and
Centrotherm InnoFlue
PP rigid venting
3"/5" (80/125 mm)
concentric (Bosch,
manufactured by M&G
Duravent)
PP-Flex
3" (80 mm) vent or air
pipe M&G Duravent
PolyPro and
Centrotherm InnoFlue
PP-Flex
2" (50 mm) vent or air
pipe M&G Duravent
PolyPro and
Centrotherm InnoFlue
PVC
Pipe cement/primer
CPVC
a. Components of the certified vent systems must not be interchanged with other vent systems or unlisted pipe fittings. Plastic components, and specified primers and glues
of the certified vent system must be from a single system manufacturer and not intermixed with other system manufacturer's vent system parts.
Table 14 Materials for pipe
Greenstar – 6721822579 (2021/01)
Did not use the chimney as a conduit if the flue gases from a wall-
mounted gas condensing boiler or other combustion equipment are
routed in or through the chimney.
All non-steel PVC/CPVC vent pipes must be glued, except for the flue gas
adapter.
The flue pipe must be supported properly and angled downward at least
¼ inch (6.35 mm) per foot from the wall-mounted gas condensing boiler.
This allows the condensate to drain away.
NOTICE
Damage of 2 inch PVC pipes.
▶ For ZBR 42-3 A and ZWB 42-3 A use 2 inch CPVC-pipes or 3 inch
pipes.
All PP/PVC/CPVC combustion air and vent pipe materials and fittings
must be approved and comply with the following:
United states
Canada
ANSI/ASTM D1785 or
BH Gas venting systems,
UL 1738
ULC S636
ANSI/ASTM D2665 or
Class IIA - PVC,Class IIB -
UL 1738
CPVC,Class IIC -
ANSI/ASTM F441 or
Polypropylene
UL 1738
(certified to ULC S636)
ANSI/ASTM D1785 or
UL 1738
ANSI/ASTM D2665 or
UL 1738
ANSI/ASTM F441 or
UL 1738
ANSI Cat IV
Approved Polypropylene
ANSI Cat IV
Approved Polypropylene
ANSI Cat IV
Approved Polypropylene
ANSI Cat IV
BH Gas venting systems,
Approved Polypropylene
ULC S636
Class IIA - PVC,Class IIB -
CPVC,
ANSI Cat IV
Class IIC - Polypropylene
Approved Polypropylene
(certified to ULC S636)
ANSI/ASTM D2564
ANSI/ASTM F493
Notes on installation and operation
X
X
X
a
,
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
a.
,
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents