displayed in indicator b/c. The current measur-
ing value is automatically converted.
The unit-of-measure setting is retained when
switching the digital level on or off.
The audio signal can be switched on/off with
the audio signal button 7. When the audio sig-
nal is switched on, indicator g appears in the
display.
When you switch on the digital level, the audio
signal is switched on as standard.
The measurement on the digital level changes
with the movement of the tool. The display
will stop on the measurement once your digital
level is stationary on the desired position.
The measurement on the display will rotate
180 degrees with the digital level, so the dis-
play can be read for overhead work.
The digital level uses arrows on the display to
show which direction it has to be tilted in or-
der to reach the target value. In standard mea-
surements the target value is the horizontal or
vertical, in the "Hold/Copy" function it is the
stored measuring value.
When the target value is reached, the arrows
disappear and a continuous audio signal
sounds when the audio signal is switched on.
The "Hold/Copy" button 11 has two functions:
– Holding ("Hold") a measured value, even
– Copying ("Copy") a measured value.
"Hold" function:
– Press the "Hold/Copy" button 11. The cur-
– Press the "Hold/Copy" button 11 again to
"Copy" function:
– Long press the "Hold/Copy" button 11. The
– Press the "Hold/Copy" button 11. The
– Place the digital level in the location to
– Press the "Hold/Copy" button 11 again to
– Long press the "Hold/Copy" button 11 to
– To delete a "Hold" value, press the "ON/
2610039976 GIM60 GIM120.indd 11
Switching the Audio Signal On/Off
Measured-value Indication
and Alignment Aids

Measuring Functions

when the digital level is moved afterwards
(e.g., because the digital level is in a posi-
tion in which the display cannot be read);
rent measuring value e is held on the dis-
play and stored, and indicator "H" flashes.
end the "Hold" function. The stored value is
deleted. Normal measuring is continued.
current measuring value e is copied and in-
dicator "H" will flash 3 times on the display
before returning to normal measuring.
stored measuring value e is shown on the
display and indicator "H" flashes.
which the measuring value is to be trans-
ferred. When doing so, the alignment of
the digital level is irrelevant. The alignment
arrows a show which direction the digital
level has to be moved in to reach the grade
you want to copy. When the stored grade
is reached, an audio signal sounds and the
alignment arrows a disappear.
return stored measurement. Indicator "H"
is shown flashing on the display.
store a new value.
OFF" button 9.