Download Print this page
Zoom 508 Operation Manual

Zoom 508 Operation Manual

Zoom operation manual ac adapter 508

Advertisement

Thank you for selecting the ZOOM 508 (hereafter simply called the "508").
Please take the time to read this manual carefully so you can get the most out of
your 508 and ensure optimum performance and reliability.
Retain this manual for future reference.
ZOOM CORPORATION
NOAH Bldg., 2-10-2, Miyanishi-cho, Fuchu-shi, Tokyo 183, Japan
PHONE: 0423-69-7116 FAX: 0423-69-7115

Major Features

1
• Compact, dedicated delay unit with up to 4000 ms delay time and eight delay
types (Four types x two variations).
• On-board "Zfx-2" DSP (Digital Signal Processor) developed by Zoom, and
an innovative design used solely for its delay effects. Achieves superior
quality delay sound on a par with high-end devices.
• You can switch between 24 patches to store diverse settings based on your
preference.
• Seamless function that enables smooth patch transitions without cutting the
delay sound when the patch is switched.
• Ample functions to support powerful live performances, including a hold
function for continuing the delay sound until the foot switch is pressed, and a
tap function for setting the delay time in the interval between when the foot
switch is pressed.
• Integrated auto-chromatic tuner for guitar. You can tune your insturment
easily anywhere, any time. You can also leave the tuning function disabled all
the time.
• The optional FP01 expression pedal enables foot control of the mix level for
the delay sound.
• Dual power supply design allows the unit to be powered from an alkaline
battery (6LR61) or an AC adapter.

Safety Precautions

2
USAGE AND SAFETY PRECAUTIONS
In this manual, symbols are used to highlight warnings and
cautions for you to read so that accidents can be prevented. The
meanings of these symbols are as follows:
This symbol indicates explanations about extremely
dangerous issues. If users ignore this symbol and handle
the device incorrectly, serious injury or death could
Warning
result.
This symbol indicates explanations about dangerous
issues. If users ignore this symbol and handle the
device the wrong way, bodily injury and damage to the
Caution
equipment could result.
Please observe the following safety tips and precautions to ensure
hazard-free use of the 508.
About power
Warning
Since power consumption of this unit is fairly high, we
recommend the use of an AC adapter whenever possible.
When powering the unit from a battery, use only an alkaline
type.
AC adapter operation
• Be sure to use only an AC adapter which supplies 9 V DC,
300 mA and is equipped with a "center minus" plug (Zoom
AD-0006). The use of an adapter other than the specified type
may damage the unit and pose a safety hazard.
• Connect the AC adapter only to an AC outlet that supplies the
rated voltage required by the adapter.
• When disconnecting the AC adapter from the AC outlet,
always grasp the adapter itself and do not pull the cable.
• If the unit is not to be used for a long time, disconnect the AC
adapter from the outlet.
Battery operation
• Use only a 9 V (alkaline) battery (6LR61).
• The 508 cannot be used for recharging.
Pay close attention to the labelling of the battery to make sure
you choose the correct type.
• If the 508 is not to be used for an extended period of time,
remove the battery from the unit.
• If battery leakage has occurred, wipe the battery compartment
and the battery terminals carefully to remove all remnants of
battery fluid.
• While using the unit, the battery compartment cover should
be closed.
Environment
Caution
Avoid using your 508 in environments where it will be
exposed to:
• Extreme temperature
• High humidity or moisture
• Excessive dust or sand
• Excessive vibration or shock
Handling
Caution
• The 508 is a precision instrument. Except for the foot
switches, do not push other parts with your feet or subject
them to strong force.
• Take care that no foreign objects (coins or pins etc.) or liquids
enter the unit.
• Be sure to turn the power to all equipment off before making
connections.
• Before moving the unit, turn the power off and disconnect all
cables and the AC adapter.
Alterations
Caution
Never open the case of the 508 or attempt to modify the
product in any way since this can result in damage to the unit.
Operation Manual
Printed in Japan 508-5000
Usage precautions
Electrical interference
For safety considerations, the 508 has been designed to provide
maximum protection against the emission of electromagnetic
radiation from inside the device, and from external
interference.However, equipment that is very susceptible to
interference or that emits powerful electromagnetic waves
should not be placed near the 508, as the possibility of
interference cannot be ruled out entirely.
Whatever the type of digital control device, the 508 included,
electromagnetic damage can cause malfunctioning and corrupt
or destroy data. Since this is an ever-present danger, thorough
care should be taken to minimize the risk of damage.
Cleaning
Use a soft, dry cloth to clean the 508. If necessary, slightly
moisten the cloth. Do not use abrasive cleanser, wax, or
solvents (such as paint thinner or cleaning alcohol), since these
may dull the finish or damage the surface.
Connecting cables and input and output jacks
You should always turn off the power to the 508 and all other
equipment before connecting or disconnecting any cables. Also
make sure to disconnect all cables and the AC adapter before
moving the 508.

Advertisement

loading

Summary of Contents for Zoom 508

  • Page 1: Major Features

    Pay close attention to the labelling of the battery to make sure you choose the correct type. • If the 508 is not to be used for an extended period of time, remove the battery from the unit. • If battery leakage has occurred, wipe the battery compartment and the battery terminals carefully to remove all remnants of battery fluid.
  • Page 2: Patch List

    What Are Banks and Patches? • PATCH A group of the settings for a certain effect type is called a PATCH. The 508 comes with 24 preset patches which can be changed (edited) by the user. • BANK The 508 calls up patches in sets of four, called a "bank".
  • Page 3: Selecting Patches

    Release immediately Tuner mode The 508 is initially set so that the auto-chromatic tuning function for the guitar activates automatically when the Bypass mode is invoked. In Bypass mode, pick an open string to be tuned. The closest note will be shown on the display.
  • Page 4 PATCH 4 PATCH 3 PATCH 4 Patch Switching (Application: Direct Load OFF) In the default condition, the 508 is DIRECT LOAD OFF set up in such a way that pressing a Keeping STORE key depressed for 1 second patch pedal immediately switches turns Direct Load off.
  • Page 5 Effect Parameters Patches in the 508 are called effect parameters, made up of elements that decide the tone. Some effect parameters decide the delay type (delay functions and characteristics), and others decide the delay time and feedback.
  • Page 6: Replacing The Battery

    Storing Patches If you have edited (altered) a patch and turn the 508 off without storing the patch, the patch will revert to its old setting. To store an edited patch, use the following simple procedure. Storing can be carried out in both Play mode and Edit mode. After you have edited the patch, press the STORE key.

This manual is also suitable for: