smoke generated in fires will rise in the air, the
detector should be installed at a higher position.
» For wall mounting, install at about 0.3-1.0 m
from ceiling.
» For ceiling mounting, install the detector at
the center of the protected area (as indicated
on the illustration).
2. Fix the detector base into a wall or ceiling with screws
and fasten the detector head on the base.
3. While installing at home, keep the detector away
from your gas stove to prevent flame roasting.
Avoid installing in places with heavy oil or
smoke that may cause false alarm or block the
gas convection holes and influence the detector
sensitivity. Also do not install the detector near to
exhaust fans, windows, doors and in places with
great vapor, e.g. in bathrooms.

OPERATION

1. Insert 2 pcs 1.5 V AA batteries into the battery
compartment. The detector enters into warm-up
status. LED flashes green.
EN
2. After about 3 minutes, the flashing green LED
goes out. And the detector goes into normal
working status. The LED flashes green once
every 30 s, indicating normal battery supply.
3. The detector should be tested periodically
during use. Short press Test & Hush Button to
OWNER'S MANUAL
16