Dimplex DXIONCF Manual

Dimplex DXIONCF Manual

Advertisement

Quick Links

DXIONCF
08/54647/0
Issue 2
As with all portable heating appliances: This product is suitable only for well insulated spaces or occasional use.
This product complies with all the required European Product Safety, Electromagnetic Compatibility and Environmental Standards. They are fully compliant
with the LVD, EMC, RoHS and Eco Design Directives

Advertisement

loading

Summary of Contents for Dimplex DXIONCF

  • Page 1 DXIONCF 08/54647/0 Issue 2 As with all portable heating appliances: This product is suitable only for well insulated spaces or occasional use. This product complies with all the required European Product Safety, Electromagnetic Compatibility and Environmental Standards. They are fully compliant...
  • Page 2: Important Safety Advice

    Important Safety Advice IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE DO NOT COVER or obstruct the air inlet and outlet openings in any way. IMPORTANT: If the mains lead of this appliance is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
  • Page 3 NEVER drop or insert any object into any openings. DO NOT use this appliance until the base is properly assembled and it is standing upright supported on and by its base only. Do not use lying down or lynig at and angle against anything. DO NOT immerse in water/other liquids or use near water to protect against electrical hazards.
  • Page 4: Remote Control

    How to assemble the base The base of the tower fan comes in two parts, each part joins together and fits around the oscillation base of the tower. The two parts have interlocking holes and bosses which easily slide/fit into each other when aligned. The back half has cable hooks and a cut-out on the edge to allow the power supply cord to exit flush with the bottom of the base.
  • Page 5: Technical Specification

    Technical Specification DXIONCF Symbol Value Unit Maximum Fan Flow Rate 22.45 m³/min Fan Power Input 36.52 Service Value 0.67 (m³/min)/W Standby Power Consumption 0.584 Fan Sound Power Level dB(A) Maximum Air Velocity 2.646 Rated Voltage 220 - 240 Rated Frequency...
  • Page 6 STANDBY Pressing the ‘STANDBY’ button turns the fan on; Pressing the button again will turn the fan off. SPEED The fan speed can be adjusted to the desired level: low (I), medium (II), or high (III) by pressing the ’SPEED’ button repeatedly until the speed required is displayed on the LED panel (shown in Fig.
  • Page 7: Cleaning And Recycling

    Display LED Can be switched off temporarily by pressing the DISPLAY button on the rermote or by pressing and holding the SPEED button on the control panel for more than 3 seconds, the display will light up again once any control button is activated.
  • Page 8 Glen Dimplex Heating & Ventilation, Grange Drive, Hedge End, Southampton SO30 2DF Telephone: 0344 879 3588 Visit: www.dimplex.co.uk [c] Glen Dimplex. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex.