5 Correct use

4.2 Function

Fig. 2: Instrument sensor operating principle
The float in the flowmeter, which is equipped with a perman-
ent magnet, is pushed past the instrument sensor by the
flow. The instrument sensor is equipped with a reed contact
chain. This enables reading out the float position.
4.2.1 GEMÜ 1270 / 1271 function
The GEMÜ 1270 / 1271 instrument sensors output the meas-
ured values as a voltage signal via a voltage divider (Rg = 10
kΩ).
4.2.2 GEMÜ 1272 / 1273 function
The GEMÜ 1272 / 1273 instrument sensors output the meas-
ured values as a 2-wire current signal 4 - 20 mA. This signal
can be directly processed.
4.3 GEMÜ CONEXO
The interaction of valve components that are equipped with
RFID chips and an associated IT infrastructure actively in-
crease process reliability.
Thanks to serialization, every valve and every relevant valve
component such as the body, actuator or diaphragm, and
even automation components, can be clearly traced and read
using the CONEXO pen RFID reader. The CONEXO app, which
can be installed on mobile devices, not only facilitates and
improves the "installation qualification" process, but also
makes the maintenance process much more transparent and
easier to document. The app actively guides the maintenance
technician through the maintenance schedule and directly
provides him with all the information assigned to the valve,
such as test reports, testing documentation and mainten-
ance histories. The CONEXO portal acts as a central element,
helping to collect, manage and process all data.
For further information on GEMÜ CONEXO please visit:
www.gemu-group.com/conexo
In the corresponding design with CONEXO, this product has
an RFID chip (1) for electronic recognition. The position of
the RFID chip can be seen below.
GEMÜ 127x
Installing the RFID chip
RFID chip

4.4 Product label

Device version
Item number
The manufacturing month is coded under the traceability
number and can be requested from GEMÜ. The product was
manufactured in Germany.
5 Correct use
Improper use of the product!
▶ Risk of severe injury or death.
▶ Manufacturer liability and guarantee will be void.
Only use the product in accordance with the operating
conditions specified in the contract documentation and
this document.
The products must:
only be used for measuring the flowmeters of the
GEMÜ 800, GEMÜ 840 and GEMÜ 850 series.
only be operated within the performance limits.
not be modified from a constructional point of view.
The product is not intended for use in potentially explosive
areas.