DISASSEMBLY AND REASSEMBLY
3-20) Ambient Thermistor
Part name
The ambient thermistor is located
inside the upper hinge cover.
Ambient
The ambient thermistor sends
Thermistor
temperature signals to the micro-
prosessor.
3-21) Door S/W & Humidity Sensor
Part name
1. Removing the upper hinge
With the door closed, remove the upper
hinge cover(1)using a screwdriver
2. Disconnect the wire
Door S/W &
Humidity
CAUTION
Sensor
3. Removing Cover Hinge sub using a
screwdriver
4. Removing Humidity sensor using a(-)
screwdriver (push designated direction)
How To Do
How To Do
When diassembling, make
sure the unit is turned off
Descriptive Picture
Descriptive Picture
35