Electrical Connection

The oven must be installed
according to the instructions
supplied.
This oven must be installed by
qualified personnel to the relevant
British Standards.
The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E -
Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
Connection
Min. size
via
Cable/flex
13 A socket
2.5 mm
outl e t
13 A spur box
Oven
2.5 mm
Control
Circuit
For Europe use only
Min. size Cable/ Cable / flex type
flex
2
2.5 mm
H07 RN-F, H05 RN-F, 15 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
Cable / flex
Fuse
type
2
3 core
13 A min.
butyl
insulated
2
PVC/PVC
15 A min.
twin and
earth
20 A max.
Fuse
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load
in compliance with the current rules.
The switch must not break the yellow and green
earth cable at any point.
the yellow and green earth cable should be 2-3 cm
longer than the other cables.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a
temperature of more than 50°C above the ambient
temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load and that the power supply is properly earthed.