  • Page 1 FULL DC INVERTER SYSTEMS KNX-02 C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5...
  • Page 3 ● This manual gives detailed description of the precautions that should be brought to your attention during operation. ● In order to ensure correct service of KNX-02 please read this manual carefully before using the unit. ● For convenience of future reference, keep this manual...
  • Page 4 Table of Contents I. Safety precautions..................1 II. Other precautions ..................3 III. Installation procedure................. 5 IV. ETS database group objects introduction ..........8...
  • Page 5: Safety Precautions

    I. Safety precautions The following contents are stated on the product and the operation manual, including usage, precautions against personal harm and property loss, and the methods of using the product correctly and safely. After fully understanding the following contents (identifiers and icons), read the text body and observe the following rules.
  • Page 6 WARNING Please entrust the distributor or professionals to install the unit. Installation by other persons may lead to imperfect installation, electric shock or fire. Strictly follow this manual. Imporper installation may lead to electric shock or fire. Reinstallation must be performed by professionals. improper installation may lead to electric shock or fire.
  • Page 7: Other Precautions

    M4X25 GB823-88 mounting screw (For Mounting on the Electrical Switch Box) Installation Manual For Mounting on the Wall Plastic expansion pipe For fixing on the 86 electrician box Plastic screw bar 3-core shielded cable For connecting the indoor unit and KNX-02...
  • Page 8 2. Prepare the following assemblies on the site. Specification Qty.(embeded Remarks Name (only for reference) into wall) 2-core shielded cable RVVP-0.5mm Max 350m 86 Electrician box Wiring Tube(Insulating Sleeve and Tightening Screw) KNX power module Communicate module Note to installation of KNX: 1.
  • Page 9: Installation Procedure

    III. Installation procedure 1.The product parameters Remarks Name Dimensions 85*51*16mm Power supply 29VDC 10mA,Supplied through KNX bus KNX programming LED indicator KNX programming button Push button Configuration with ETS software. Configuration 2.The product parameters ① KNX-02 ② ③ ④...
  • Page 10 ETS database (*.vd*)of KNX-02 can be downloaded from our web site: https://www.sinclair-solutions.com in B2B section, or consult our company. 3. Wiring installation instruction The Wiring diagram follows,the KNX-02 connect to the indoor Unit and KNX Power. KNX TP-1 (EIB)bus MAX 500m...
  • Page 11 The Introduction KNX-02 ● KNX-02 allows monitoring and control, fully bi-directionally, of all the functioning parameters of Sinclair SDV5 from KNX installations. ● Simple installation. Can be installed inside the own indoor unit, it connects directly in one side to the electronic circuit of the indoor unit (cable supplied) and in the other side to the KNX TP-1 (EIB) bus.
  • Page 12: Ets Database Group Objects Introduction

    IV.ETS database group objects introduction...
  • Page 13 The instruction as follow: 1: set mode; database type: DPT_20.102 HVAC Mode; set value:0-OFF ; 1-Fan only; 2-Cool; 3-Heat ; 4-Auto; 5-Dry 2: set temp; database type: DPT_9.001 temperature(°C). The indoor unit temperature value corresponding to ETS temperature value: Temp. value(℃) ETS value Temp.
  • Page 14 6: Set Auxiliary Heater ON/OFF; Data type: DPT_1.001 Switch. Set value: 0-Auxiliary Heater OFF 1-Auxiliary Heater ON. This function is only available for heat mode. 7: Set Heat temp;database type: DPT_9.001 temperature(°C).; 8: Mode status read; data type: DPT_20.102 HVAC mode Read value: 0-OFF.1-Fan ;...
  • Page 15 21:Set Dry mode; data type: DPT_1.001 switch Set value: 1-set as Dry mode 22:Set Fan mode; data type: DPT_1.001 switch Set value: 1-set as Fan mode 23:Set mode +/-; data type: DPT_1.008 UpDown Set value: 0-Down 1-UP 24: Set temperature +/-; data type: DPT_1.008 UpDown Set value: 0-Down 1-UP 25: The fan speed +/-;data type: DPT_1.008 UpDown Set value: 0-Down 1-UP...
  • Page 16 SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD Great Britain www.sinclair-world.com This product was manufactured in China (Made in China). REPRESENTATIVE SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic TECHNICAL SUPPORT SINCLAIR Global Group s.r.o. Purkynova 45...