Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Quick Links

IMPORTANT SAFETY INFORMATION
GB
Please read and understand this entire manual before attemp-
ting to assemble, operate or install the product.
• For use with Plug & Go LED landscape lighting products
ONLY.
• Maximum load (combined wattage of all fixtures) connec-
ted to the transformer should NOT exceed 23 W.
• Wire intended for shallow burial (less than 15 cm deep).
• Install all fixtures at least 3 m away from pools, spas or
fountains.
• Keep fixtures away from materials that may burn.
• DO NOT touch lens, guard or fixture housing when in use.
• DO NOT operate or install a fixture with missing or dama-
ged parts.
• DO NOT touch the LED at any time as this will damage the
fixture.
• DO NOT submerge the fixture in the water as this will
damage the fixture.
• Mount transformer vertically at least 30 cm above ground.
• Suggest using with the drainage system and ensure no
water after installation
• Luminaires are not designed to be used in areas where
motor vehicles may circulate, carriageways, parking
areas, etc.
• Rated load in 1500 N (150 kg)
CAUTION
• This product is not a toy. Keep away from children.
• Do not connect this fixture to an electrical system that is
not earthed.
• The external flexible cable or cord of this luminaire cannot
be replaced; if the cord is damaged, the luminaire should
be disposed of.
• The light source of this luminaire is not replaceable; when
the light source reaches its end of life the whole luminaire
should be replaced.
ASSEMBLY AND INSTALLATION INSTRUCTIONS
FIXTURE ASSEMBLY (fig. 1)
Dig a hole for fixture (A) according to the dimensions below.
Insert fixture (A) into the hole, securing with the excess dirt or
decorative rock/stones (not included).
Note: DO NOT use a hammer. For ground with hard soil, soften
soil by pouring water into the area or create a pilot hole with a
gardening tool. DO NOT attempt to use your weight to push the
fixture into the ground.
130.0mm
A
Fig. 1
MULTIPLE FIXTURES INSTALLATION (fig. 2)
Step 1
Lay out fixtures at desired locations. Any combination of lights
is acceptable as long as the total wattage does not exceed
23 W.
Step 2
Connect female connector from transformer to male connector
of the closest light.
Step 3
Continue connecting the female connector from the first light
to the male connector of the next light. Repeat until all fixtures
are connected.
Note: fixtures are pre-wired with a 1.5m male lead and a
1.5m female lead for a total of 3m. If your layout requires
shorter distance between fixtures, roll up the excess wire and
bury. If more distance between fixtures is required, 3m and
6m extensions are available (sold separately). If your layout
requires you to branch into two different directions, a splitter is
available (sold separately). When you come to the end of your
run, cover the cap that was removed from the transformer
female lead (see TRANSFORMER INSTALLATION step 3) onto
the female lead of the last fixture.
Step 4
Cover wire with ground cover or bury.
(1.5m)
Fig. 2
TRANSFORMER INSTALLATION (fig. 3)
Step 1
Select a transformer or Plug & Go lighting set.
Step 2
Locate a 230 V Power outlet to plug in transformer.
Step 3
Locate the female lead with connected 4.5 m wire coming
from the transformer. Remove the cap (save for later use) and
run wire to location of first fixture.
Note: if additional wire is needed to reach fist fixture, 3 m and
6 m extensions are available (sold separately).
Step 4
The 2
wire lead coming from the transformer is the photo
nd
sensor. This should be placed in a spot where it will receive
ambient outdoor light, but no direct light from porch lights,
streetlights, etc. The photo sensor will allow for automatic
dusk and dawn operation.
Step 5
Connect the power plugs on the transformer to the outlet and
proceed to turn on assembly.
Note: If the transformer is plugged in and photo sensor is
covered, the lights will illuminate.
LV201ORBT-DU
female
connector
male
connector
(1.5m)
(1.5m)
(1.5m)
1

Advertisement

Table of Contents
loading

Summary of Contents for Duracell LV201ORBT-DU

  • Page 1 LV201ORBT-DU IMPORTANT SAFETY INFORMATION MULTIPLE FIXTURES INSTALLATION (fig. 2) Please read and understand this entire manual before attemp- Step 1 ting to assemble, operate or install the product. Lay out fixtures at desired locations. Any combination of lights is acceptable as long as the total wattage does not exceed •...
  • Page 2: Care And Maintenance

    For assistance, email: techsupport@duracell-light.com, call • Before attempting to clean the fixture, disconnect power by +49 (0)40 - 51 48 40 48 or visit: www.duracell-light.com. turn off the power supply and remove the transformer. • To clean fixture, use a dry or slightly damp, clean WICHTIGE SICHERHEITSHINWEISE cloth.
  • Page 3: Pflege Und Wartung

    weibliche • Das Leuchtmittel dieser Leuchte ist nicht auswechselbar, Anschluss- weshalb die gesamte Leuchte ersetzt werden muss, wenn buchse die Lebensdauer des Leuchtmittels beendet ist. männlicher Anschluss- stecker ZUSAMMENBAU- UND INSTALLATIONSANWEISUNGEN ZUSAMMENBAU DER ARMATUR (Abb. 1) Graben Sie ein Loch für die Armatur (A) entsprechend den (1.5m) (1.5m) (1.5m)
  • Page 4: Fehlersuche

    Vidis GmbH, Rungedamm 37, 21035 Hamburg à creuser à l’aide d’un outil de jardin. N’ESSAYER PAS d’enfon- Hilfe erhalten Sie per E-Mail: techsupport@duracell-light.com, cer l’appareil dans le sol en lui appliquant votre poids. Telefon +49 (0) 40 - 51 48 40 48 oder unter:...
  • Page 5: Entretien Et Maintenance

    Remarque : si vous avez besoin de câble supplémentaire pour 130.0mm atteindre le premier luminaire, des rallonges de 3 m et 6 m sont disponibles (vendues séparément). Étape 4 Le 2e câble provenant du transformateur est le capteur de lu- mière.
  • Page 6: Vigtige Sikkerhedsoplysninger

    Vidis GmbH, Rungedamm 37, 21035 Hambourg, Allemagne Pour obtenir de l‘aide, envoyez un courriel à: Fig. 1 techsupport@duracell-light.com, appelez le +49 (0) 40 - 51 48 40 48 ou visitez: www.duracell-light.com. INSTALLATION AF FLERE ARMATURER (fig. 2) Trin 1 VIGTIGE SIKKERHEDSOPLYSNINGER Placér armaturerne på...
  • Page 7 30cm Producent: Vidis GmbH, Rungedamm 37, 21035 Hamburg E-mail: techsupport@duracell-light.com, Tlf.: hunstik +49 (0) 40 - 51 48 40 48 eller besøg: www.duracell-light.com. hanstik VIKTIG SIKKERHETSINFORMASJON (4.5mtr) (1.5mtr) Fig. 3 Vennligst les og forstå denne hele håndboken før du prøver å...
  • Page 8: Stell Og Vedlikehold

    • IKKE bruk eller installer en armatur med manglende eller du kjøpe forlengelseskabel på 3 og 6 meter (selges separat). skadede deler. Hvis du trenger en avgrening i to forskjellige retninger, kan du • IKKE berør LED-lampen da dette vil ødelegge armaturen. kjøpe en splitter (selges separat).
  • Page 9 130.0mm Produsent: Vidis GmbH, Rungedamm 37, 21035 Hamburg For assistanse, email: techsupport@duracell-light.com, ring +49 (0) 40 - 51 48 40 48 eller besøk: www.duracell-light.com. VIKTIG SÄKERHETSINFORMATION Var god läs och förstå hela denna manual innan du försöker Fig. 1 montera, använda eller installera produkten.
  • Page 10: Skötsel Och Underhåll

    Steg 3 Fortsätt ansluta honkontakten från den första lampan till han- kontakten på nästa lampa. Upprepa tills samtliga armaturer är anslutna. transformator OBS! Armaturerna är redan försedda med en 1,5-meters fotos- hanledare och en 1,5-meters honledare för en total längd på 3 ensor m.
  • Page 11: Korrekt Avfallshantering Av Produkten

    återvinning Tillverkare: Vidis GmbH, Rungedamm 37, 21035 Hamburg, Tyskland För hjälp, email: techsupport@duracell-light.com, ring +49 (0) 40 - 51 48 40 48 eller besök: www.duracell-light.com. Kuva 1 TÄRKEÄÄ TURVALLISUUSTIETOA USEIDEN VALAISIMIEN ASENTAMINEN (kuva 2) Lue nämä ohjeet kokonaan ja varmista, että ymmärrät ne, Vaihe 1 ennen kuin yrität koota, käyttää...
  • Page 12: Hoito Ja Kunnossapito

    +49 (0) 40 - 51 48 40 48 tai käy osoitteessa: valoanturi www.duracell-light.com. 30cm © 2018 DURACELL, Bethel, CT 06801. Duracell is a registered trademark of Duracell Batteries BVBA and Duracell U.S. Operations, Inc., used under license. All rights reserved. naarasliitin urosliitin (4.5m)

Table of Contents