5. Connect the air line quick coupler (D). Turn on air.
Open air valve (W). Air should flow from the mix
chamber nozzle (N).
N
NOTE: If excessive noise is heard, or air is felt coming
from behind the retaining ring (U), the fluid cartridge (Y)
is not fully engaged into the fluid housing (F).
A loose fluid cartridge can result in equipment
damage and splashing chemical.To prevent damage
to the fluid o-ring or injury from splashing chemical,
verify that the cartridge is fully engaged into the fluid
housing, and the front retaining ring (U) is tight.
6. Disengage the piston safety lock (L).See Piston
Safety Lock, page 20.
L
7. Trigger gun to check for full mix chamber travel. The
front of the air cap (C) should be approximately
flush with the front retaining ring (U).
U
C
3A7314B
W
D
TI2414-1A
TI2410A
TI2414-1A
8. Open cleanoff air valve (K) 1/4-1/2 turn and trigger
gun to check that cleanoff air is flowing. Adjust as
desired.
K
9. Engage the piston safety lock (L). See Piston
Safety Lock, page 20.
L
10. Turn on proportioner.
11. Open B (RESIN) fluid valve (about three half turns).
Then open A (ISO) fluid valve.
12. Disengage the piston safety lock (L).See Piston
Safety Lock, page 20.
L
Installation
TI2413A
TI2409A
TI2414A
TI2410A
15