Wiring - Mitsubishi Electric 800 Series Instruction Manual

Plug-in option, analog output function, digital output function
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

2.3

Wiring

1.
For the wiring, strip off the sheath of a cable, and use it with a blade terminal. For a single wire, strip off the sheath of the
wire and apply directly. Insert the blade terminal or the single wire into a socket of the terminal.
Strip off the sheath as shown below. If too much of the wires is stripped, a short circuit may occur with neighboring wires.
If not enough of the wire is stripped, wires may become loose and fall out.
Twist the stripped end of wires to prevent them from fraying. Do not solder it.
Crimp the blade terminal.
Insert wires to a blade terminal, and check that the wires come out for about 0 to 0.5 mm.
Check the condition of the blade terminal after crimping. Do not use a blade terminal of which the crimping is
inappropriate, or the face is damaged.
CAUTION
• After wiring, wire offcuts must not be left in the inverter. They may cause a fault, failure or malfunction.
18
INSTALLATION
Cable sheath stripping length
10mm
Damaged
Wires are not inserted
Crumpled tip
into the sleeve
Unstranded
wires

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8ay e kit

Table of Contents