Installation Map; Select The Best Location - LG ASNQ092BRW0 Manual

Inverter single wall mounted r410a(60hz) 6rmi0-05a(replaces 6rmi0-04c)
Table of Contents

Advertisement

Inverter Single
13. Installation

Installation Map

- The feature can be changed according
a type of model.
NOTICE
(h) You should purchase the installation parts

Select the best Location

Indoor unit
1. There should not be any heat or steam near the unit.
2. Select a place where there are no obstacles around of
the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left (or
right) of the unit is more than 100mm. The unit should
be installed as high as possible on the wall, allowing a
minimum of 200mm from ceiling.
6. Use a metal detector to locate studs to prevent
unnecessary damage to the wall.
Install the indoor unit on the wall where the height from the floor is more than 2300mm.
Saddle
.
More than
100
More than 2300
Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealant)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
Vinyl tape (Wide)
• Apply after carrying out a
drainage test.
• To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
More than 200
More than
Inverter Single-60Hz(R410A)
100
(Unit : mm)
_ 101