4. Technical data

Motor supply voltage: ...............................12V DC
Idling speed: .......................... 0-350/0-1300 min
Torque settings: ........................................... 19+1
Clockwise/Counter-clockwise: ........................Yes
Clamping range of drill chuck: .......... max. 10 mm
Battery charge voltage: .......................... 12 V DC
Battery charge current: ................................ 0.5 A
Battery charger supply voltage: ....... 230 V ~ 50Hz
Charging time: ..............................max. 3-5 hours
Battery type: ............................................... Li-Ion
Weight: ..........................................................1 kg
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 62841.
L
sound pressure level ..................... 83.1 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ....................... 94.1 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 62841.
Drilling in metal
Vibration emission value a
K uncertainty = 1.5 m/s
Screwing without hammer action
Vibration emission value a
K uncertainty = 1.5 m/s
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Anl_TH_CD_12_2_Li_SPK9.indb 16
Anl_TH_CD_12_2_Li_SPK9.indb 16
-1
≤ 2.5 m/s
2
h
2
=10.77 m/s
2
h
2
- 16 -
GB
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.

5. Before starting the equipment

Be sure to read the following information before
you put the cordless screwdriver into operation:
1. Charge the battery only with the charging unit
supplied.
2. Only ever use sharp drill bits and screwdriver
bits which are suitable for the purpose and in
faultless condition.
3. Always check for concealed electric cables
and gas and water pipes when drilling and
screwing in walls.
15.05.2019 11:46:23