Specifications - Pentair Autotrol Performa 400 Series Service Manual

Table of Contents

Advertisement

SPECIFICAtIoNS

Hydrostatic Test Pressure
Working Pressure
Standard Electrical Rating
Optional Electrical Rating
Electrical Cord (standard rating)
Pressure Tank Thread
Riser Pipe Diameter Required
Riser Pipe Length
Standard Connection
Optional Connections
Brine Line Connection
Drain Line Connection
Optional Bypass Valve
Control Module, Tank Adapter
Rubber Goods
Brine Refill Control
Injector Size "A" White
Injector Size "B" Blue
Injector Size "C" Red
Injector Size "D" Green
Internal Backwash Controllers
All sizes to flow 4.5 gpm/sq ft (183 L/m/m2) of bed area.
For tank sizes above 14 inches in diameter, use an external flow control.
10 • Autotrol
Performa Valve with 400 Series Control water Conditioning Control System
®
DAYS
CLOCK
300 psi (20.69 bar)
20-125 psi (1.38 - 8.62 bar)
115V 60 Hz
115V 50 Hz, 230V 50 Hz, 200V 60Hz, 24V 60 Hz, 24V 50 Hz, 100V 60 Hz, 100V 50 Hz, 12V 50 Hz/
transformer, 12V 60 Hz/transformer
60-inch (1.5 m) 3-wire with plug
2-1/2 inch-8 male
1.050 inch OD (26.7 mm)
1-1/8 ±1/8 inches (31.8 mm) higher than the top of mineral tank
1-inch (25.4-mm) copper tube adapters
3/4-inch, 22-mm, and 28-mm copper tube adapters 3/4-inch BSPT, 1-inch BSPT, 1-inch NPT
stainless steel pipe adapters 3/4-inch, 1-inch, 25-mm CPVC tube adapters
3/8-inch NPT male
3/4-inch NPT male
Rotating handles, full 1-inch porting, reinforced plastic
Reinforced plastic
Compounded for cold water service
1 to 10 lbs (0.45 to 4.5 kg) of salt or 3 to 19 lbs (1.4 to 8.6 kg) of salt
Nozzle .042-inch (1.1 mm) diameter, Throat .089-inch (2.3 mm) diameter
Nozzle .052-inch (1.3 mm) diameter, Throat .099-inch (2.5 mm) diameter
Nozzle .059-inch (1.5 mm) diameter, Throat .099-inch (2.5 mm) diameter
Nozzle .071-inch (1.8 mm) diameter, Throat .147-inch (3.7 mm) diameter
7- through 14-inch (17.8 though 35.6 cm) diameter media tanks