Interlogix AS580 Installation Sheet

Sounder with level

Advertisement

Quick Links

AS580 Sounder with Level Installation Sheet
AS580 features
Spirit level on top of the back plate to correctly align the
AS580
Low profile polycarbonate box with the strobe lens
integrated into the lens
Quick release cradle contains the PCB for easy servicing
Highly weather resistant
Easy wiring
Easy diagnostics using the LEDs
Two siren standard
4.7 kΩ end of line (EOL) resistor built in
Tamper switch to protect against removal of cover or
removal from surface
Mounting Instructions
Use the spirit level included on the back plate to correctly align
the AS580.
Make sure that the tamper switch is properly fitted.
AS580 LEDs
Table 1: LED modes
Jled link
LED mode
Not cut
LED flashes (1Hz)
Cut
LED on steady
If an alarm is caused by a power or tamper failure, the LEDs
will operate as follows: 1 LED on steady, 1 LED flashes.
The LEDs can be turned off by removing the four-wire
(male/female) connector.
Board layout
Figure 1: Board layout
© 2019 UTC Fire & Security Americas Corporation, Inc.
Wiring the CSx75 control panel
Figure 2: Wiring the CSx75 control panel
Wiring the CS250, CS2512, CS234, and
CS245 control panels
Figure 3: Wiring the CS250, CS2512, CS234, and CS245 control
panels
Note:
When the interconnection cable length exceeds 10 m,
program the siren tamper circuit as an isolated tamper loop
(Jtl jumper cut/open) and wire tamper pins TR and TL
individually to the CS panel:
TR = CS250 pin 23
TL = Aux. ground (GND)
P/N 146145999-2 (EN) • REV E • ISS 28FEB19
1 / 4

Advertisement

loading

Summary of Contents for Interlogix AS580

  • Page 1 AS580 Sounder with Level Installation Sheet AS580 features Wiring the CSx75 control panel • Spirit level on top of the back plate to correctly align the Figure 2: Wiring the CSx75 control panel AS580 • Low profile polycarbonate box with the strobe lens integrated into the lens •...
  • Page 2 Wiring two AS580s together Wiring the CD95 control panel Figure 4: Wiring two AS580s together Figure 6: Wiring the CD95 control panel Wiring the CD34/CS450 control panel Wiring the CD72 control panel Figure 5: Wiring the CD34/CS450 control panel Figure 7: Wiring the CD72 control panel P/N 146145999-2 (EN) •...
  • Page 3 Wiring the CS350 control panel Wiring the Advisor Advanced control panel Figure 8: Wiring the CS350 control panel Figure 10: Wiring the Advisor Advanced control panel Wiring the HKC control panel Figure 9: Wiring the HKC control panel Specifications Voltage [1] 10.0 to 14.5 V (12 V nom.) Standby current LEDs off...
  • Page 4 (Hg). For proper recycling return the battery to your supplier or to a designated collection point. For more information see www.utcfssecurityproducts.eu/recycle/ Contact information www.utcfireandsecurity.com or www.interlogix.com For customer support, see www.utcfssecurityproducts.eu P/N 146145999-2 (EN) • REV E • ISS 28FEB19 4 / 4...