Haier HPU-42CV03 Service Manual page 6

Hide thumbs Also See for HPU-42CV03:
Table of Contents

Advertisement

item
Function
Capacity
Capacity
Sensible heat ratio
Total power input
Max. power input
EER or COP
Dehumidifying capacity
Power cable
Signal cable
Connecting cable
Wired control cable
for wired control unit
Power source
Running /Max.Running current
Start Current
Class of anti electric shock
Circuit breaker
Max. operating pressure of heat side
Max. operating pressure of cold side
Unit model (color)
Type × Number
Speed(H-M-L)
Fan
Fan motor output power
Air-flow(H-M-L)
Type / Diameter
Heat exchanger
Total Area
Temp. scope
External
Dimension
Package
Air sending angle
Drainage pipe (material , I.D./O.D.)
Control type
(Remote /wired /model)
Fresh air hole dimension
Outlet distribution hole dimension
Electricity Heater
Noise level
(H-M-L)
Weight
(Net / Shipping)
External
Dimension
Package
Weight
(Net / Shipping)
Unit model (color)
Model / Manufacture
Oil model
Oil type
Compressor
Oil charging
Type
Protection type
Starting method
Type × Number
Speed
Fan
Fan motor output power
Air-flow(H-M-L)
Type / Diameter
Heat exchanger
Row / Fin pitch
Temp. scope
External
Dimension
Package
Drainage pipe (material , I.D./O.D.)
Refrigerant control method
Defrosting
Volume of Accumulator
Noise level
Type of Four way valve
material of reduce noise
crankcase heater power
Weight
(Net / Shipping)
Type / Charge
Refrigerant
Recharge quantity
Liquid
Pipe
Gas
Connecting Method
MAX.Drop
Between I.D &O.D
MAX.Piping length
Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB
Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level.
The detailed method please refer to the following information:
Commercial Air Conditioner
Model
BTU/h
W/W
10‐³×m³/h
section
section
section
section
N, V, Hz
A / A
r/min
(L×W×H)
mm×mm×mm
(L×W×H)
mm×mm×mm
dB(A)
kg / kg
(L×W×H)
mm×mm×mm
(L×W×H)
mm×mm×mm
kg / kg
r/min
(L×W×H)
mm×mm×mm
(L×W×H)
mm×mm×mm
mm/mm
dB(A)
kg / kg
cooling
41000
kW
12.0
70%
W
3700
W
4400
3.24
/
3N,380-400V,50HZ
Cooling 6.9A/7.8A Heating 7.0/8.3
A
CLASS I
A
2.8
Mpa
2.8
Mpa
HPU-42HV03(WHITE)
kW
m³/h
mm
inner grooved/φ7
1850×600×350
1980×660×420
mm
mm
mm
kW
HPU-42HV03(WHITE)
VR54KS-TFP-542/COPELAND
Inner thermal protection
kW
m³/h
inner grooved/φ9.52
mm
1090*410*1350
mm
L
W
g
g/m
mm
mm
m
m
Model: HPU-42CV03
HPU-42HV03
HPU-42HV03
heating
44000
13.0
4000
4900
3.25
5.0
2
5G×2.5mm
2
4G×0.75mm
/
50
CLASS I
20
2.8
2.8
centrifugal
430/405/370
0.09
1750
0.45
Remote
/
/
51
59/70
/
/
/
3GS
1360
SCROLL
hard startup
Axial*2
840
0.06
6000
2/1.6
948*340*1250
Capillary tube
Automatic
/
59
/
/
40
106/111
R22/3400
65
φ9.52
φ19.05
Flared
30
50