4. EMC COUNTERMEASURE PARTS
[SF1252, SF1253 wire connection method]
1) Peel the wire insulator.
2) Insert the core of the cable into the opening, and tighten with the slotted screwdriver. In addition,
connect the cables to the terminals of SF1252 or SF1253 in a one-to-one connection.
EMC filter
SF1252
SF1253

4.3 Ferrite core (Data line filter)

Noise can be prevented by installing a data line filter onto the cables connected to the servo amplifier. The data
line filter in the following is one such example.
Model
ZCAT3035-1330
(Manufactured by TDK)
Note. The above values of impedance do not refer to the guaranteed values but the impedance values of the data line filter
including those of the cable (measured reference values).
ESD-SR-250 by NEC TOKIN, E04SRM563218 by SEIWA ELECTRIC, etc. are also available.
[Usage example]
Passing through once
Flat bladed screwdriver
Insulator
Screw size
Tightening torque
2.5mm
3mm
(Note) Impedance ( )
10 to 100MHz
100 to 500MHz
80
Passing through twice
Wire
9mm
Core
14mm
0.598N m
0.794N m
150
Passing through three times
4 - 7
Core length for SF1252
Core length for SF1253