PROGRAMMING
Cooling Example:
1. In cool, press Auto Schedule once.
2. Press
or
to select a comfortable cooling tempera-
ture (example 75°).
3. Press Auto Schedule again. Your thermostat is now pro-
grammed for 75° for all cooling time periods.
Your cooling program for each day of the week will look like
this:
6:30
75°
8:00
75°
5:00
75°
10:30
75°
Energy Saving Factory Pre-Program
The 1F95-1291 thermostats are programmed with the energy saving settings shown in the table below for all days of the week.
If this program suits your needs, simply set the thermostat clock and press the RUN key.
The table below shows the factory set heating and cooling schedule for all days of the week.
Heating Program
Cooling Program
* You can eliminate these two program periods in the confi guration menu (reference #5) if the building is occupied all day.
Day period will change to 6:00 AM and 70° and can be programmed as required.
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The 1F95-1291 comes confi gured for 7 day programming and can also be confi gured for 5+1+1 programming (see confi gura-
tion section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your
own times and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day schedule, fi ll in all lines with the times and temperatures you want.
Keep the following guidelines in mind when planning your program.
• In Heating, lower temperatures will save energy.
• In Cooling, higher temperatures will save energy.
• If you plan on using Auto Changeover, do not program the heating temperature higher than the cooling temperature.
13
* Wake Up
Leave For Work
(Morning)
6:00 AM
70°F
8:00 AM
6:00 AM
75°F
8:00 AM
Programmable Fan Option
In the Set Schedule (programming mode) pressing Fan will
alternate the fan setting between FAN Auto and FAN Prog.
FAN Auto runs the fan as needed with the heating or cooling.
FAN Prog programs the fan to run continuously for the heat-
ing or cooling time period you are programming.
Example: Press the SYSTEM key to select Heat.
Press the Menu key once to display Set Schedule.
Press Set Schedule once to display the 1st heating program
period. The time and temperature for this period will show on
the display. Press the FAN key until it displays FAN Prog. The
fan is now programmed to run continuously for this time pe-
riod. The fan can be programmed for any or all time and tem-
perature settings in heating and cooling. To cancel program
fan for a time period, enter the heating or cooling program
(Menu, Set Schedule) and advance to the time/temperature
period you want to cancel. Press the fan key and FAN Prog
will change to FAN Auto.
* Return Home
(Day)
(Evening)
62°F
5:00 PM
83°F
5:00 PM
Go To Bed
(Night)
70°F
10:00 PM
62°F
75°F
10:00 PM
78°F