Specifications
Cable length
Switch close resistance
Switch open resistance
Mounted on non ferromagnetic material:
Minimum mounting distance
between contact and magnet
Approach distance X (switch close)
Removal distance X (switch open)
Approach distance Y (switch close)
Removal distance Y (switch open)
Approach distance Z (switch close)
Removal distance Z (switch open)
Mounted on ferromagnetic material:
Minimum mounting distance
between contact and magnet
Approach distance X (switch close)
Removal distance X (switch open)
Approach distance Y (switch close)
Removal distance Y (switch open)
Approach distance Z (switch close)
Removal distance Z (switch open)
Contact type
Contact dimensions
Magnet dimensions
Bracket dimensions
Maximum switch voltage
Maximum switch current
Operating temperature
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Environmental
IP68
class
Certification
2 / 4
2,5 m
< 2 Ω
> 10 MΩ
Refer to Figure 3
25 mm
29 mm ±30%
32 mm ±30%
62 mm ±25%
81 mm ±15%
63 mm ±30%
85 mm ±20%
Refer to Figure 3
5 mm
24 mm ±40%
27 mm ±35%
26 mm ±35%
39 mm ±20%
24 mm ±30%
34 mm ±25%
Change-over
76.2 x 25.4 x 12.7 mm
76.2 x 25.4 x 12.7 mm
73 x 47 x 19 mm
30 V
0.25 A
−40 to +65°C
EN 50131 Class II: −10 to
+55°C
or scan the QR code.
EN 50131
EN 50131-2-6:2008
Security Grade 2, Class II
SSF 1014v4, Larmklass 2
Tested and certified by Applica Test &
Certification, Norway
European Union
UTC Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.utcfireandsecurity.com or
www.interlogix.com.y
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/
Contact information
www.utcfireandsecurity.com or www.interlogix.com.
For customer support, see www.utcfssecurityproducts.eu
SV: Installationsanvisning
Beskrivning
DC115 är en förspänd utanpåliggande magnetkontakt som kan
anslutas till ett inbrottslarm. DC115 kan användas på
ferromagnetiska och icke-ferromagnetiska grindar och dörrar.
Montering
Kontaktdelen och magneten skall monteras med skruvar
parallellt med varandra och med texten vänd åt samma håll (se
Figure 1). Använd monteringsfästen som visas i figur 2 om det
behövs. Eftersom detta är en förspänd kontakt finns det ett
minsta monteringsavstånd mellan den magnetiska kontakten
och magneten. Detta avstånd är:
För icke-ferromagnetiskt material: minimum 25 mm mellan
magnetkontakten och magneten.
För ferromagnetiskt material: minimum 5 mm mellan
magnetkontakten och magneten.
Vid installationen måste brytavstånden ställas in individuellt för
varje kontakt.
När installationen är klar måste den brytade funktion i
magnetkontakten kontrolleras (till exempel med en
kontinuitetsprovare eller multimeter). Användning av mekanisk
kraft vid installation, kan skada glaskroppen på reedswitchen.
Vid installation, ta hänsyn till att dörrar kan påverkas
Notering:
av temperatur och kan röra sig.
Kabelbeskrivning
Färg
Nr
2X svart, märkt supervised loop
1.
2.
Svart
P/N 1069823 (ML) • REV D • ISS 23OCT18
Beskrivning
Sabotage, övervakad slinga
Larm, COM