Siemens DMS8000 MP4 Series Installation And Configuration Manual page 12

Add-on module
Table of Contents

Advertisement

Configuration
5
Configuration procedure
12
Building Technologies
Fire Safety & Security Products
Adding the MultiScope node
1. Select the new folder.
2. Click the Video menu
3. Select the Geutebrueck DVR icon
Note: You can customise the default name of the new node typing in a new name in
the Description field of the Node tab.
Configuring the MultiScope variant and addresses
1. Select new MultiScope node and click the Node tab.
2. Select the model and variant of the DVR.
Note: By default, the model is set to the first option (4 camera inputs). If necessary,
open the drop-down list of the 'Device Type' field and select one of the other
options. The list includes:
- MSC2+/4, MSC2+/4C, MSC2+/4CI: 4 camera inputs
- MSC2+/8: 8 camera inputs
- MSC2+/16: 16 camera inputs
- MSC2+/32: 32 camera inputs
- MSC2+/2x4: 8 camera inputs (dual speed)
- MSC2+/4x4: 16 camera inputs (quad speed)
- MSC3/4: 4 camera inputs
- MSC3/8: 8 camera inputs
- MSC3/16: 16 camera inputs
- MSC3/32: 32 camera inputs
- MSC3/2x4: 8 camera inputs (dual speed)
- MSC3/4x4: 16 camera inputs (quad speed)
The Device Type selection only affects the number of camera inputs that are
available in the Composer tree. Note that the device type cannot be set to a
smaller model. Be aware that you can safely operate with a configuration larger
than the actual device.
3. Fill in the address fields:
a. Local address: Enter a value from 0 to 99 according to the actual DVR setting
(refer to the MultiScope documentation).
b. IP address, which should match the value set in the MultiScope (refer to the
MultiScope documentation).
MultiScope DVR settings
.
to add a MultiScope node.
A6V10067796_a_en