Step Three: Clean regulator and decontaminate after use

When done using the regulator, it is important to clean the regulator and decontaminate yourself.
Do not store the regulator when saturated with chemicals, as it is unsafe and could also result in
damage to the equipment.
Cleanup and decontamination procedures must be followed after each use.
Improper equipment cleanup and disposal of chemicals can result in dangerous chemical
exposure to humans and the environment, as well as equipment damage.
Personal decontamination is required after spraying to minimize unsafe exposure to chemicals
and potential illness.
1. Drain pump
system
2. Unused
chemical
3. Flush
regulator
4. Decontaminate
& launder
Operation – Using the Regulator
WARNING
If there is excess pesticide left in the system, drain the system:
a) Disconnect power to the pump and relieve system pressure.
b) Find a suitable container in which to drain the unused pesticide.
c) While wearing rubber gloves, eye protection, and all other required
personal protective equipment, allow pesticide to drain into container.
Properly store or dispose of unused chemical:
a) If the unused pesticide is to be stored for future use:
Store all unused pesticide in its original, or a suitably marked,
container in a secure location out of the reach of children & animals.
b) If remaining pesticide is to be disposed:
Properly dispose of the remaining chemical and its container per the
chemical manufacturer's recommendation and according to local
hazardous waste disposal regulations.
Flush the regulator per the chemical manufacturer's
recommendations. A general procedure is as follows:
a) Add fresh water to the pump system.
b) Reconnect power to the pump.
c) Operate the pump system and discharge all rinse water onto an area
that can accept dilute pesticide application.
d) Add 5 gallons of the chemical manufacturer's recommended cleaning
solution. Operate the pump system, collecting the discharged solution
if recommended by the manufacturer.
e) After flushing, disconnect power to the pump and be sure all system
pressure is relieved.
f) Dispose of cleaning solution discharge as recommended by the
manufacturer of the solution.
Decontaminate yourself after you are finished handling chemicals:
a) Remove all clothing worn during spraying and chemical handling.
b) Wash all exposed parts of the body with soap and water.
c) Launder clothing separately from other wash.