Diagnostics

12.1

Overview

General information about faults and alarms
The errors and states detected by the individual components of the drive system are
indicated by messages.
The messages are categorized into faults and alarms.
Properties of faults and alarms
● Faults
– Are identified by Fxxxxx.
– Can lead to a fault reaction.
– Must be acknowledged once the cause has been remedied.
– Status via control unit and LED RDY.
– Status via PROFINET status word ZSW1.3.
– Entry in the fault buffer.
● Alarms
– Are identified by Axxxxx.
– Have no further effect on the drive.
– The alarms are automatically reset once the cause has been remedied. No
– Status via Control Unit and LED RDY.
– Status via PROFINET status word ZSW1.7.
– Entry in the alarm buffer.
● General properties of faults and alarms
– Triggering on selected messages possible.
– Contain the component number for identifying the affected SINAMICS component.
– Contain diagnostic information on the relevant message.
Message class
For each message, specifies the associated message class with the following structure:
Text of the message class (number according to PROFIdrive)
The message classes that are available are shown in the table below, which provides the
text of the message class, their number according to PROFIdrive, and a brief help text
regarding the cause and remedy.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2020, A5E37208830-008
acknowledgement is required.
12