Err_Check - HELIX DM422 User Manual

Fully digital stepping driver
Table of Contents

Advertisement

st
Figure 26: 1
Anti -Resonance Tuning (Speed=0.98rps)

Err_check

Error Check: This window shows both the present status of each error event and their history.
l
Current error event(s) can be reset by clicking Erase Current Err! button, and all error events
can be reset by clicking Erase All! button. List of the last ten drive faults. #0 being the most
recent, #9 is the oldest. See Figure 27.
Figure 27: Error check window
Toll Free 1-855-435-4958
DM422 Digital Stepping Drive Manual V1.0
28
Web Site: www.helixlinear.com
OverCurrent: Over-current Protection. Protection will be activated when continuous current
exceeds 16A.
OverVoltage: Over-voltage Protection. When power supply voltage exceeds 42±1 VDC, protection
will be activated.
PhaseErr: Phase Error Protection. Motor power lines wrong & not connected will activate this
protection.
ErrCounter: Displays current error(s) and current error history.
Erase Current Err!: Erase Current Err button. The user can clear current error(s) by clicking this
button.
Erase All!: Erase All! button. The user can clear all error(s) including error history by clicking this
button.
Toll Free 1-855-435-4958
DM422 Digital Stepping Drive Manual V1.0
29
Web Site: www.helixlinear.com