Installer Menu Items 117 through 122
Item
Function
117
FACT DEFAULT
118
POWER SAVINGS
119
DATA CHANNEL
121
UPDATE TIME HR
122
UPDATE TIME MN

Detailed Descriptions of Installer Menu Items

000 - INSTALLER SEQUENCE
Specifies entry sequence to the Installer Menu.
0 = 9876
1 = 4321
2 = 1478
3 = 3698
001 - POWER MANAGE (Power Management)
Energy saving feature. Determines the number of hours, in the
range 1 to 7, of inactivity allowed, either at the TV control panel
or from the remote, before the TV automatically turns itself OFF. If
set to 0, Power Management is disabled.
002 - AC ON (AC Power Switchable)
Detemines the status of the TV when AC power is applied. Set to
0 (default) for standard TV turn ON/OFF operation. Set to 16 if you
would like the TV to turn ON the first time AC power is applied, after
which the TV will be configured for standard ON/OFF operation.
If set to 1 or 17, the TV will turn ON when AC power is applied.
Pressing the POWER button is not necessary. This is desirable if
the TV is plugged into a switched AC outlet (i.e., a set-top box).
Though note that if the Pro:Centric application is loaded (i.e.,
item 098 PRO:CENTRIC is not set to 0), the TV will reboot and
initiate an update once every 24 hours. During the update event,
the TV checks for and downloads any available updates from the
Pro:Centric server (item 119 DATA CHANNEL set from 1 to 135 or
253). The time at which this event occurs depends on the setting of
item 121 UPDATE TIME HR. See item 119 and 121 descriptions
for further information. Once the update cycle is complete, the TV
completes the reboot and resumes its ON state.
Note: If set to 1 or 17, the TV does not respond to ON/OFF
commands from either the remote or the display panel, and the
Sleep Timer is also nonfunctional.
Set to 2, 3, 18, or 19 to enable the Instant ON feature, as required.
The Instant ON feature allows the TV to turn ON when AC power
is applied, but with video and audio muted (Muted ON). The TV
remains powered ON while appearing to be OFF. Pressing the
POWER button toggles off/on the video and audio mutes, so that
206-4342
Value Range
Default Value
0 / 1
0
1, 3, 7
3
0 – 135, 255
255
0 – 23, 128, 255
128
0 – 59
0
Brief Description of Function
Set to 1 to restore the factory default settings of all Installer Menu items.
Determines the powered status of the embedded b-LAN module and the GAME
CONTROL/MPI port. See detailed descriptions.
Set to 0 to disable. Set from 1 to 135 to match the RF channel number used
by the Pro:Centric server as its data channel. Set to 255 to use Auto Search
to find the Pro:Centric RF channel. See detailed descriptions.
Sets the Wake For Update hour. See detailed descriptions.
Sets the Wake For Update minute. See detailed descriptions.
the TV appears to turn ON instantly. Set to the appropriate value
to enable Instant ON with reboot (value 2 or 18) or Instant ON
without reboot (value 3 or 19), respectively. See bullets below for
further information on reboot functionality. See also note below.
Note: Values 2 and 3 represent standard Instant ON functionality;
i.e., when AC power is applied, the TV is in a Muted ON state. If
set to 18 or 19, the Instant ON feature allows the TV to turn ON,
without muting video and audio, when AC power is initially applied.
Instant ON with reboot: The TV will reboot and, if applicable (i.e.,
item 119 DATA CHANNEL set from 1 to 135 or 253), check for
and download any available updates from the Pro:Centric server
at every turn OFF. This setting is not recommended if the TV will
be configured with a resident application.
Instant ON without reboot: The TV will not reboot to check for and
download updates at turn OFF, with the following exception: the
first time the TV is turned OFF after this item is set to 3 or 19, the
TV will reboot and initiate an update event (Data Channel Auto
Search and/or check for and download of updates—see also
paragraph below). This setting is recommended if the TV will be
configured with a resident application. In this mode, the standard
check for and download of updates is under application control.
Refer to your site-specific documentation for further information
on configuring the TV with a resident application.
When this item is set to 2, 3, 18, or 19, the TV also will reboot and
initiate an update event once every 24 hours. During the update
event, the TV, as applicable, performs a Data Channel Auto Search
(item 119 set to 255) and/or checks for and downloads any
available updates from the Pro:Centric server (item 119 set from
1 to 135 or 253). The time at which this event occurs depends
on the setting of item 121 UPDATE TIME HR. See item 119 and
121 descriptions for further information. Once the update cycle is
complete, the TV completes the reboot and resumes its Muted ON
state.
Note: Instant ON is not supported when the TV is in MPI-EXT
Mode, EBL-LNT Mode, or FTG Mode via EBL.