Download Print this page

Whirlpool 50 Installation Instructions Manual

Whirlpool ice maker model number: 50

Advertisement

Quick Links

ICE MAKER
Model 50
ave Ovens, Compactors, Room Air Conditioners, Dehumidifiers, Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers,Oishwasl

Advertisement

loading

Summary of Contents for Whirlpool 50

  • Page 1 ICE MAKER Model 50 ave Ovens, Compactors, Room Air Conditioners, Dehumidifiers, Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers,Oishwasl...
  • Page 2: Changing The Bin Door Panel

    Changing the bin door panel The storage bin door is designed to accept an optional decorative wood panel of your choice. The wood panel should be no more than l/4 inch (6 mm) thick. Cut it to the same size as the production panel.
  • Page 3: For The Plumber

    4. Remove all tape and packaging material from the outside and inside of the cabinet. See Figure 4. 5. Remove the front grill; take out the screws securing the grill at the bottom and lift it free of cabinet. 6. Turn the fan by hand to make certain it moves freely. 7.
  • Page 4 BACK VIEW -17.7/w-c ’ 4” LONG DRAIN TUBE OPEN DRAIN HOLE SUPPIED FITTING l-l/Z” ORDER CONDENSATE FROM YOUR WHIRLPOOL (1%” CONDENSATE SWITCH THAT CYCLES on drain (See from FIGURE 5 ; 5/S” I.D. RUBBER: - RUN TO FOR FIELD WATER PUMP KIT NO.
  • Page 5: For The Electrician

    REMOVE PLUG CONDENSATE PUMP For the electrician Electrical requirements A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical supply is required (time delay fuse or circuit breaker is recommended). It is recommended circuit, serving only this appliance, be provided. NOT use an extension cord.
  • Page 6 How it works Compressor runs Condenser fan runs Water pump runs (circulates water) Cutter grid is warm to touch WHEN DESIRED THICKNESS IS REACHED, HARVEST CYCLE BEGINS AND THE FOLLOWING HAPPENS: Evaporator thermostat is satisfied Compressor keeps running Condenser fan stops or turns very slowly Water pump stops Hot gas solenoid opens Water inlet valve opens...
  • Page 7 Unit wiring diagram This model operates at 115 volts except for the cutter grid circuit which operates at 8.5 volts at 1 amp. The compressor runs at all times except when the bin thermostat becomes satisfied and opens up. This de- energizes the system except for the transformer cutter grid.
  • Page 8 Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers, Dishwashers, Built-In Ovens and Surface Units, Ranges, Microw, Makincyour world a little easier. In the event your WHIRLPOOL appliance should appliance or a WHIRLPOOL franchised TECH-CARE@ telephone directory listed under “Appliances-Household-Major-Service name number...