2.3 Achieving Optimal Performance

Optimal performance for the COOL, HEAT, and DRY modes can be achieved in
the following temperature ranges. When your air conditioner is used outside of
these ranges, certain safety protection features will activate and cause the unit to
perform less than optimally.
Optimal performance temperature ranges
Room Temperature
E-Star (9K ~ 24K)
Outdoor
Hyper Heat (9K ~ 24K)
Temperature
LCAC (30K ~ 60K)
Table 1
When the outside temperature is below 0°C (32°F ), we strongly
recommend keeping the unit plugged in at all times to ensure smooth
ongoing performance. A base pan heater is used in the outdoor unit to
prevent ice build-up. Ice may build up if the unit is unplugged.
Bosch Thermotechnology Corp. | 06.2019
Bosch Climate 5000 Series Ducted Type (Medium & High Static) Air Conditioner / Heat Pump | 7
DRY mode
COOL mode
HEAT mode
17ºC - 32ºC
0ºC - 30ºC
10ºC - 32ºC
63ºF - 90ºF
32ºF - 86ºF
50ºF - 90ºF
-25ºC - 50ºC
-25ºC - 30ºC
0ºC - 50ºC
-13ºF - 122ºF
-13ºF - 86ºF
32ºF - 122ºF
-30ºC - 50ºC
-30ºC - 30ºC
0ºC - 50ºC
-22ºF - 122ºF
-22ºF - 86ºF
32ºF - 122ºF
-15ºC - 50ºC
-15ºC - 30ºC
0ºC - 50ºC
5ºF - 122ºF
5ºF - 86ºF
32ºF - 122ºF

2.4 Other Features

Auto-Restart
If the unit loses power, it will automatically restart with the prior settings
once power has been restored.
Anti-Mildew
When turning off the unit from COOL, AUTO (COOL), or DRY modes,
the air conditioner will continue operating at very low power to dry up
condensed water and prevent mildew growth.
Louver Angle Memory (some models)
When turning on your unit, the louver will automatically resume its former
angle.
Refrigerant Leakage Detection
The indoor unit will automatically display "EC" when it detects refrigerant
leakage or another internal error which requires professional service.
For a detailed explanation of your unit's advanced functionality (such as
TURBO mode and its self-cleaning functions), refer to the Remote
Control Manual.