Danfoss Optyma Blue OP-LGHE068NTA07D Instructions Manual

Danfoss Optyma Blue OP-LGHE068NTA07D Instructions Manual

Advertisement

Quick Links

Instructions
Optyma™ Blue
Condensing units
H
D
1 x coil height
Silent block
© Danfoss | DCS (CC) | 2019.01
W
Min. clearance: 2 x unit length
Fig.2
Fig.4
Code
114X8056 OP-LGHE068NTA07D
114X8057
114X8058 OP-LGHE108NTA07D
114X8059 OP-LGHE136NTA07D
114X8060 OP-LGHE215NTA07D
114X8048 OP-LGHE271NTA07D
114X8061 OP-MGZE038MTA07G
114X8062 OP-MGZE048MTA07D
114X8063 OP-MGZE060MTA07D
114X8064 OP-MGZE086MTA07D
114X8065 OP-MGZE108MTA07D
114X8066 OP-MGZE136MTA07D
114X8067 OP-MGZE171MTA07D
114X8068 OP-MGZE215MTA07D
8 to 12 m/s
at min. capacity
max. 4m
Model Name
Refrigerant
OP-LCHE096NTA07D
R404A/R507
R404A/R507,
R134a
8 to 12 m/s
at max. capacity
Fig.3
AN293820378892en-000101 | 1

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss Optyma Blue OP-LGHE068NTA07D

  • Page 1 1 x coil height Min. clearance: 2 x unit length 8 to 12 m/s at min. capacity Fig.2 8 to 12 m/s at max. capacity max. 4m Silent block Fig.4 Fig.3 © Danfoss | DCS (CC) | 2019.01 AN293820378892en-000101 | 1...
  • Page 2 D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz) D: 50Hz Voltage range 3 Phases :342V ~ 440V G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz) G: 50Hz Voltage range 1 Phase :200V ~ 264V © Danfoss | DCS (CC) | 2019.01 2 | AN293820378892en-000101...
  • Page 3 D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz) D: 50Hz Voltage range 3 Phases :342V ~ 440V G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz) G: 50Hz Voltage range 1 Phase :200V ~ 264V © Danfoss | DCS (CC) | 2019.01 AN293820378892en-000101 | 3...
  • Page 4 Instructions Factory setting For R404A models HP (bar) LP (bar) © Danfoss | DCS (CC) | 2019.01 4 | AN293820378892en-000101...
  • Page 5: Table Of Contents

    HFC refrigerants are being used. All brazing ma- plate or in the application guidelines. terial is to contain a minimum of 5% silver. © Danfoss | DCS (CC) | 2019.01 AN293820378892en-000101 | 5...
  • Page 6: Leak Detection

    For further details, refer to the condensing unit to the compressor and/or compromise safety cause motor winding damage (motor burn-out). guidelines. device operation, thereby resulting in potential injury to personnel. © Danfoss | DCS (CC) | 2019.01 6 | AN293820378892en-000101...
  • Page 7: Start Up

    Repeat oil and © Danfoss | DCS (CC) | 2019.01 AN293820378892en-000101 | 7...
  • Page 8: User Advisory

    Pressure inside the compressor and refrige- • Presence of rust or water inside the condensing rant circuit can reach dangerously high levels unit circuit, (e.g. abnormal operation, fire,…) leading to © Danfoss | DCS (CC) | 2019.01 8 | AN293820378892en-000101...

This manual is also suitable for:

Optyma blue op-lche096nta07dOptyma blue op-lghe108nta07dOptyma blue op-lghe136nta07dOptyma blue op-lghe21snta07dOptyma blue op-lghe271nta07dOptyma blue op-mgze038mta07g ... Show all

Table of Contents