Download Print this page

3M Breathe Easy PAPR Cleaning And Storage

Advertisement

Quick Links

3M™ Breathe Easy™ PAPR with Butyl Rubber Hood and RBE-57
After each use, the PAPR Unit and its components should be appropriately
cleaned and sanitized. Cleaning procedures must be site-specific and based on
known or suspected contaminants.
1. Routine Cleaning Information
a. The hood, blower, battery pack and breathing tube may be
wiped down with a damp towel or sponge.
b. Cleaning solutions containing petroleum based solvents or
lanolin should not be used as these may damage plastic items.
c. Do not immerse the blower, battery pack or breathing tube.
d. The PAPR unit, battery, breathing tube and all other
components are not designed for sterilization by irradiation,
ethylene oxide or steam autoclaving and may be permanently
damaged by these methods.
2. Cleaning and disinfection of the butyl rubber hood:
a. Remove the hood from the breathing tube
b. Wash the hood in mild soap and warm water.
c. You may disinfect with 3M™ Twist 'n Fill™ 5L quat. Follow
product user instructions for Twist 'n Fill 5L quat. An alternate
cleaning and disinfecting solution is a hypochlorite solution (1 oz.
[30ml] household bleach in 2 gallons [7.5 L] of water).
d. Rinse hood thoroughly in warm, fresh water.
e. Hang hood vertically and allow to air dry.
3.
Use the following suggested procedures for cleaning your
system:
a, After having disconnected the breathing tube from any attached
headgear.
b. Remove the battery and the PAPR blower unit from the waist
belt or vest and set aside.
– Cleaning and Storage

Advertisement

loading

Summary of Contents for 3M Breathe Easy PAPR

  • Page 1 Remove the hood from the breathing tube b. Wash the hood in mild soap and warm water. c. You may disinfect with 3M™ Twist ‘n Fill™ 5L quat. Follow product user instructions for Twist ‘n Fill 5L quat. An alternate cleaning and disinfecting solution is a hypochlorite solution (1 oz.
  • Page 2 Follow product user instructions for Twist ‘n Fill 5L quat. Wash the belt in soapy water. You may disinfect the belt using 3M Twist ‘n Fill Quat Solution or a 1 to 4 household bleach. m. Air dry in an uncontaminated atmosphere, the temperature...
  • Page 3 You’ll only get the protection this respirator can provide if you wear it at all times you are exposed to contaminants. Your life and health depend on it. This concludes the 3M Breathe Easy Butyl Rubber Hood with Loose Fitting PAPR and Cartridge RBE57 Training. © 3M April 2007. All rights reserved.

This manual is also suitable for: