The following terms are used in these instructions to bring attention to presence of hazards of various risk levels, or to important
information concerning the life of the product.
Indicates presence of hazard which
WARNING
can cause severe personal injury,
death or substantial property damage.
Failure to follow items below can cause severe personal injury, death or substantial property damage:
WARNING
These instructions are for use by a qualified installer/service technician. Follow all instructions in proper order.
Shut off main gas valve and disconnect electricity to boiler.
Wait until boiler is cooled down before proceeding with replacement.
Contents of Kit:
2" square cut seals
Silicone sealant
Nuts and washers for draw rods
Instructions
Instructions for blower removal/replacement
1. Remove jacket top and front panels. Lay aside boiler
insulation.
2. Close isolation valves between boiler and system.
Drain boiler.
3. Remove:
All wiring connectors from control tray.
Control tray (if applicable).
External system gas and water piping from boiler.
Thermostat wiring.
External vent piping.
External combustion air piping, if used.
Vent condensate drain hose.
Blower assembly and burner. See "Blower Assembly
or Burner Replacement Instructions," part number
550-141-608, packed with kit.
High limit control bulb from well.
Relief valve and external piping (back section only).
External air vent piping.
Remaining outside and interior jacket panels.
Block temperature limit switch.
Circulator(s).
4. Tilt block assembly onto back section to rest on 2
short pieces of 2 x 4's.
Section block is heavy - care must be
CAUTION
taken in moving to avoid personal
injury.
5. DO NOT remove drain valve and all other remaining
piping on front section.
6. Remove base rail assembly and tie rods from block
assembly.
GV BOILER
GV BOILER
GV BOILER
GV BOILER
GV BOILER
Intermediate or Back Section Repair Kit
Part Number 382-200-305
Replacement Instructions
Replacement Instructions
Replacement Instructions
Replacement Instructions
Replacement Instructions
Indicates presence of hazard which will
CAUTION
or can cause minor personal injury or
property damage.
7. Remove section(s) to be changed.
8. Remove silicone sealant from mating sections.
9. Clean new section and mating sections of any oil
and dirt or silicone sealant will not adhere properly.
10. Clean square cut sealing surfaces on new and
mating sections.
Do not use any cleaner containing
CAUTION
petroleum-based distillate (oil). Square
cut seal failure will occur.
11. Apply bead of silicone sealant around perimeter of
intermediate or back section except on inside of
waterway holes (see Figure 1).
Figure 1
12. Insert new square cut seals.
13. Align new section and lay it on top of existing section.
Repeat steps 10-12 as necessary.
Part number 550-141-588/0501
Silicone
Sealant
Do Not
Apply
Silicone
Sealant
Here
Do Not
Apply
Silicone
Sealant
Here

Advertisement

loading

Summary of Contents for Weil-McLain GV BOILER 382-200-305

  • Page 1 The following terms are used in these instructions to bring attention to presence of hazards of various risk levels, or to important information concerning the life of the product. Indicates presence of hazard which WARNING can cause severe personal injury, death or substantial property damage.
  • Page 2 23. Check for flue gas leakage around new section using mirror. Leaks will cause fog on mirror. Repair any leaks with silicone sealant and recheck. 24. Replace insulation and jacket right, back, front and top panels. Michigan City, IN 46360-2388 http://www.weil-mclain.com Part number 550-141-588/0501 Weil-McLain 500 Blaine Street...