Technical Information
Product specification
Model name
Modes
Nominal thermal store tank volume
Overall unit dimensions
Weight (empty)
Weight (full)
Primary expansion vessel
Nominal volume
(Accessory item)
Charge pressure
Safety device
Water circuit
Control thermistor (THW1)
(Thermal store tank)
Control thermistor (THW3)
Pressure relief valve (2 No. devices)
Flow sensor
Manual reset thermostat
Booster heater
Manual reset thermostat
Thermal Cut-out
(for dry run prevention)
Primary circuit circulating
Thermal store and space heating
pump
Hot water supply
Connections
Primary circuit
Secondary (potable) circuit
Target temperature range
Space heating
Flow temperature *1
Room temperature
DHW supply maximum temperature
Guaranteed operating range
Ambient *2
Outdoor temperature
Electrical data
Control board
Power supply
Current
Breaker
(Local supply)
Booster heater
Power supply
Capacity
Current
Breaker
Sound power level
Maximum secondary (potable) water supply pressure
Maximum primary working pressure
Minimum primary working pressure
*1 Depending on the ambient conditions, it may not reach the set temperature.
*2 The cylinder's environment MUST be frost-free.
EHPT20Q-VM2EA
Space & DHW heating
200 L
1600 × 595 × 680 mm (Height × Width × Depth)
77 kg
283 kg
18 L or 25 L
1.0 bar (100 kPa)
42 - 72°C
80 °C
3.0 bar (300 kPa)
Min. flow 1.3 L/min
90 °C
90 °C
121 °C
Grundfos Solar PML 25-145 180
Grundfos Solar PML 25-145 180
φ 22.0
φ 22.0
25 - 60 °C
10 - 30 °C
40 - 70 °C
0 - 35 °C (80%RH)
- 15 - 35 °C
(Phase, voltage, frequency)
230V N〜 50 Hz
12.8 A
20 A
230V N〜 50 Hz
(Phase, voltage, frequency)
2 kW
8.7 A
16 A
40 dB(A)
10 bar (1 MPa)
2.5 bar (250 kPa)
1.0 bar (100 kPa)
<Table 3.1>